Multi-frequency simultaneous measurement of bioimpedance spectroscopy based on a low crest factor multisine excitation
Authors:
- 13 February 2015
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 36 (3) , 489-501
Abstract
Bioimpedance spectroscopy (BIS) is becoming a powerful diagnostic tool for a wide variety of medical applications, and the multi-frequency simultaneous (MFS) measurement of BIS can greatly reduce measurement time and record the transient physiological status of a living body compared with traditional frequency-sweep measurement technology. This paper adopts the Van der Ouderaa’s multisine, which has 31 equidistant and flat amplitude spectra and a low crest factor of 1.405 as the broadband excitation, and realizes the MFS measurement of BIS by means of spectral analysis using the fast Fourier transform algorithm. The approach to implement the multisine based on a field-programmable gate array and a digital to analog converter is described in detail, and impedance measurement experiments are performed on three resistance-capitance three-element phantoms. Experimental results show a commendable accuracy with a mean relative error of 0.55% for the impedance amplitudes, and a mean absolute error of 0.20° for the impedance phases on the 31 frequencies ranging linearly from 32 to 992 kHz. This paper validates the feasibility of the MFS technology for BIS measurement based on the multisine excitation.Keywords
This publication has 46 references indexed in Scilit:
- Harmonic impedance spectra identification from time-varying bioimpedance: theory and validationPhysiological Measurement, 2013
- A new measuring and identification approach for time-varying bioimpedance using multisine electrical impedance spectroscopyPhysiological Measurement, 2013
- Electrical Impedance Spectroscopy as Electrical Biopsy for Monitoring Radiation Sequelae of Intestine in RatsBioMed Research International, 2013
- Broadband excitation for short-time impedance spectroscopyPhysiological Measurement, 2008
- Eliminating the picket fence effect of the fast Fourier transformComputer Physics Communications, 2008
- Harmonic components of leakage current as a diagnostic tool to study the aging of insulatorsJournal of Electrostatics, 2008
- High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequencesLab on a Chip, 2007
- Peak factor minimization of input and output signals of linear systemsIEEE Transactions on Instrumentation and Measurement, 1988
- A new method for synthesis of low-peak-factor signalsIEEE Transactions on Acoustics, Speech, and Signal Processing, 1987
- Synthesis of low-peak-factor signals and binary sequences with low autocorrelation (Corresp.)IEEE Transactions on Information Theory, 1970