Visualization of embolism formation in the xylem of liana stems using neutron radiography
Open Access
- 7 February 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Botany
- Vol. 111 (4) , 723-730
Abstract
Cold neutron radiography was applied to directly observe embolism in conduits of liana stems with the aim to evaluate the suitability of this method for studying embolism formation and repair. Potential advantages of this method are a principally non-invasive imaging approach with low energy dose compared with synchrotron X-ray radiation, a good spatial and temporal resolution, and the possibility to observe the entire volume of stem portions with a length of several centimetres at one time. Complete and cut stems of Adenia lobata, Aristolochia macrophylla and Parthenocissus tricuspidata were radiographed at the neutron imaging facility CONRAD at the Helmholtz-Zentrum Berlin für Materialien und Energie, with each measurement cycle lasting several hours. Low attenuation gas spaces were separated from the high attenuation (water-containing) plant tissue using image processing. Severe cuts into the stem were necessary to induce embolism. The formation and temporal course of an embolism event could then be successfully observed in individual conduits. It was found that complete emptying of a vessel with a diameter of 100 µm required a time interval of 4 min. Furthermore, dehydration of the whole stem section could be monitored via decreasing attenuation of the neutrons. The results suggest that cold neutron radiography represents a useful tool for studying water relations in plant stems that has the potential to complement other non-invasive methods.Keywords
This publication has 49 references indexed in Scilit:
- The Dynamics of Embolism Repair in Xylem: In Vivo Visualizations Using High-Resolution Computed TomographyPlant Physiology, 2010
- X-ray and neutron imaging – Complementary techniques for materials science and engineeringInternational Journal of Materials Research, 2010
- Neutron Imaging Resolution Improvements Optimized for Fuel Cell ApplicationsElectrochemical and Solid-State Letters, 2010
- In situ observation of the water distribution across a PEFC using high resolution neutron radiographyElectrochemistry Communications, 2008
- Advanced Tomographic Methods in Materials Research and Engineering2008
- In vivo magnetic resonance imaging of xylem vessel contents in woody lianasPlant, Cell & Environment, 2003
- Relations between stomatal closure, leaf turgor and xylem vulnerability in eight tropical dry forest treesPlant, Cell & Environment, 2003
- Mechanisms of xylem recovery from winter embolism in Fagus sylvaticaTree Physiology, 2001
- Neutron Imaging Technique for In Situ Measurement of Water Transport Gradients within Nafion in Polymer Electrolyte Fuel CellsJournal of the Electrochemical Society, 1999
- Gas Penetration of Pit Membranes in the Xylem of Rhododendron as the Cause of Acoustically Detectable Sap CavitationAustralian Journal of Plant Physiology, 1985