Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscope
- 15 May 2010
- journal article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 13 (2) , 121-125
Abstract
The objective of this study was to make an elasticity distribution image of natural arteries in a liquid environment at high resolution at the micrometer level and at a wide area at the sub-square millimeter level by improving the scanning haptic microscope (SHM), developed previously for characterization of the stiffness of natural tissues. The circumferential sections (thickness, 1.0 mm) of small-caliber porcine arteries (approximately 3-mm diameter) were used as a sample. Measurement was performed by soaking a probe (diameter, 5 μm; spatial resolution, less than 2 μm) in saline solution at an appropriate depth. The vascular tissues were segregated by multi-layering a high elasticity region with mainly elastin (50.8 ± 13.8 kPa) and a low one with mainly collagen and smooth muscle cells (17.0 ± 9.0 kPa), as observed previously in high humidity conditions. The elasticity was measured repeatedly with little change for over 4 h in a liquid environment, which enabled observation with maintenance of high precision of a large area of at least 1,200 × 100 μm, whereas the elasticity was increased with time by the dehydration of samples with shrinkage in the air, in which an averaged elasticity in the overall area was approximately doubled within 2 h. This simple, inexpensive system allows observation of the distribution of the surface elasticity at the extracellular matrix level of vascular tissues in a liquid environment close to the natural one.Keywords
This publication has 18 references indexed in Scilit:
- Preparation of in-vivo tissue-engineered valved conduit with the sinus of Valsalva (type IV biovalve)Journal of Artificial Organs, 2010
- Tactile Mapping SystemInnovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2009
- Local elasticity imaging of vascular tissues using a tactile mapping systemJournal of Artificial Organs, 2009
- Development of an in vivo tissue-engineered, autologous heart valve (the biovalve): Preparation of a prototype modelThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Development of biotube vascular grafts incorporating cuffs for easy implantationJournal of Artificial Organs, 2007
- Soft tissue elastometerMedical Engineering & Physics, 2007
- Atomic-Scale Structure and Electrostatics of Anionic Palmitoyloleoylphosphatidylglycerol Lipid Bilayers with Na+ CounterionsBiophysical Journal, 2007
- Elastic Response, Buckling, and Instability of Microtubules under Radial IndentationBiophysical Journal, 2006
- A pinch elastometer for soft tissueMedical Engineering & Physics, 2006
- Assessment of Elasticity and Topography of Aspergillus nidulans Spores via Atomic Force MicroscopyApplied and Environmental Microbiology, 2005