Thin-Film Glucose Biosensor Based on Plasma-Polymerized Film: Simple Design for Mass Production
- 4 May 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (11) , 2671-2675
Abstract
We propose a simple thin-film glucose biosensor based on a plasma-polymerized film. The film is deposited directly onto the substrate under dry conditions. The resulting films are extreme thin, adhere well onto the substrate (electrode), and have a highly cross-linked network structure and functional groups, such as amino groups, which enable a large amount of enzyme to be immobilized. Since this design allows fabrication through a dry process, with the exception of the enzyme immobilization, which is the last stage of the process, the chip fabrication can be designed as a full-wafer process to achieve mass production compatibility. The resulting sensors produced using this film are more reproducible, exhibit lower noise, and reduce the effect of interference to a greater degree than sensors made using conventional immobilization methods, e.g., via 3-(aminopropyl)triethoxysilane. The obtained film is a good interfacial design between enzyme and electrode; enzyme two-dimensionally locates very close to the electrode in a manner that is quite reproducible. Therefore, a wide dynamic range (up to 60 mM) and rapid response time (11.5 ± 0.8 s) were obtained. Because of its highly cross-linking network structure, the amperometric response due to interferences such as ascorbic acid and acetaminophen was reduced by size discrimination of plasma-polymerized films.Keywords
This publication has 31 references indexed in Scilit:
- Polyurethane–acrylate photocurable polymeric membrane for ion-sensitive field-effect transistor based urea biosensorsAnalytica Chimica Acta, 1999
- Plasma-polymerized films for biosensorsTrAC Trends in Analytical Chemistry, 1999
- Microfabricated glucose biosensor with glucose oxidase entrapped in sol–gel matrixTalanta, 1998
- Dynamic Electrochemistry: Methodology and ApplicationAnalytical Chemistry, 1998
- Film formation and crack development in plasma polymerized hexamethyldisiloxanePolymer Engineering & Science, 1997
- Fabrication and Characterization of Sputtered-Carbon Microelectrode ArraysAnalytical Chemistry, 1996
- Microfabricated amperometric creatine and creatinine biosensorsAnalytica Chimica Acta, 1996
- Portable device for continuous fractionated blood sampling and continuous ex vivo blood glucose monitoringBiosensors and Bioelectronics, 1996
- Plasma-Polymerized Thin Films for Enzyme Immobilization in BiosensorsAnalytical Letters, 1989
- Ultrathin coating of plasma polymer of methane applied on the surface of silicone contact lensesJournal of Biomedical Materials Research, 1988