Fabrication of a bismuth nanoparticle/Nafion modified screen-printed graphene electrode for in situ environmental monitoring
- 19 February 2019
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 11 (12) , 1591-1603
Abstract
Bismuth nanoparticle (BiNP)/Nafion modified screen-printed electrodes were fabricated through screen printing and drop coating. Detection of lead (Pb2+) and cadmium (Cd2+) was performed via anodic stripping voltammetry (ASV). Optimum values of the deposition time (60 seconds) and scan rate (50 mV s−1) were obtained and utilized in the selection of the best BiNP modifier concentration of 1.0 mg. The fabricated electrodes were optimized by cyclic voltammetry, scanning electron microscopy, and energy dispersive X-ray spectroscopy. The limit of detection was found to be 280 parts per trillion and 40.34 parts per billion (ppb) for lead and cadmium, respectively. Real samples of filtered tap water, unfiltered tap water, treated wastewater, and water obtained from Manila Bay were analyzed through ASV and atomic absorption spectroscopy (AAS). The Manila Bay water samples contained lead and cadmium levels far beyond safe limits set forth by the U.S. EPA and World Health Organization while trace amounts of lead (1–2 ppb) were detected in the other water samples. The treated wastewater contained the least amount of lead while the unfiltered tap water contained the highest concentration of lead. Nonetheless, these trace amounts are well within tolerance levels set forth by government agencies. The presence of heavy metals in all water samples was validated by AAS analysis.Keywords
Funding Information
- National Research Council of the Philippines (G-67)
This publication has 34 references indexed in Scilit:
- Recent Trends in Macro-, Micro-, and Nanomaterial-Based Tools and Strategies for Heavy-Metal DetectionChemical Reviews, 2011
- Antimony ToxicityInternational Journal of Environmental Research and Public Health, 2010
- In situ bismuth film modified screen printed electrodes for the bio-monitoring of cadmium in oral (saliva) fluidAnalytical Methods, 2010
- Toxicity and cellular uptake of gold nanoparticles: what we have learned so far?Journal of Nanoparticle Research, 2010
- Simultaneous preconcentration of copper, zinc, cadmium, and nickel in water samples by cloud point extraction using 4-(2-pyridylazo)-resorcinol and their determination by inductively coupled plasma optic emission spectrometryJournal of Hazardous Materials, 2009
- Linear sweep anodic stripping voltammetry of heavy metals from nitrogen doped tetrahedral amorphous carbon thin filmsElectrochimica Acta, 2009
- An electrochemical sensor based on the reduction of screen-printed bismuth oxide for the determination of trace lead and cadmiumSensors and Actuators B: Chemical, 2008
- Development of disposable bulk-modified screen-printed electrode based on bismuth oxide for stripping chronopotentiometric analysis of lead (II) and cadmium (II) in soil and water samplesAnalytica Chimica Acta, 2008
- Heavy metal contamination of soil and vegetables in suburban areas of Varanasi, IndiaEcotoxicology and Environmental Safety, 2007
- Heavy-metal ion sensors using chitosan-capped gold nanoparticlesScience and Technology of Advanced Materials, 2005