Snap-on Adaptor for Microtiter Plates to Enable Continuous-Flow Microfluidic Screening and Harvesting of Crystalline Materials
Open Access
- 23 October 2023
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (44) , 41502-41511
Abstract
Microtiter plate assay is a conventional and standard tool for high-throughput (HT) screening that allows the synthesis, harvesting, and analysis of crystals. The microtiter plate screening assays require a small amount of solute in each experiment, which is adequate for a solid-state crystal analysis such as X-ray diffraction (XRD) or Raman spectroscopy. Despite the advantages of these high-throughput assays, their batch operational nature results in a continuous decrease in supersaturation due to crystal nucleation and growth. Continuous-flow microfluidic mixer devices have evolved as an alternate technique for efficiently screening crystals under controlled supersaturation. However, such a microfluidic device requires a minimum of two inlets per micromixer to create cyclonic flow, thereby creating physical limitations for implementing such a device for HT screening. Additionally, the monolithic design of these microfluidic devices makes it challenging to harvest crystals for post-screening analysis. Here, we develop a snap-on adapter that can be reversibly attached to a microtiter plate and convert it into a continuous-flow microfluidic mixer device. The integration of the snap-on adapter with a flow distributor and concentration gradient generator provides greater control over screening conditions while minimizing the number of independent inlets and pumps required. The three-dimensional (3D)-printed snap-on adaptor is plugged into a 24-well plate assay to demonstrate salt screening of naproxen crystals. Different naproxen salts are crystallized using four different salt formers (SFs)-sodium hydroxide, potassium hydroxide, pyridine, and arginine-and four different solvents-ethanol, methanol, isopropyl alcohol, and deionized water. The wells are further inspected under an optical microscope to identify their morphological forms and yields. The crystals are then harvested for solid-state characterization using XRD and Fourier transform infrared spectroscopy, followed by measurement of their dissolution rates. The flexibility of the snap-on adapter to fit on a wide range of microtiter plates and the ease in harvesting and analyzing crystals postscreening are two significant advantages that make this device versatile for various applications.Keywords
Funding Information
- Enabling Technology Consortium
This publication has 20 references indexed in Scilit:
- Design and evaluation of microfluidic devices for two-dimensional spatial separationsJournal of Chromatography A, 2016
- A 3D-Printed Oxygen Control Insert for a 24-Well PlatePLOS ONE, 2015
- An evaluation of salt screening methodologiesJournal of Pharmacy and Pharmacology, 2015
- Microfluidic titer plate for stratified 3D cell cultureLab on a Chip, 2013
- A microfluidic platform for pharmaceutical salt screeningLab on a Chip, 2011
- Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactorSensors and Actuators B: Chemical, 2010
- Titer plate formatted continuous flow thermal reactors for high throughput applications: fabrication and testingJournal of Micromechanics and Microengineering, 2010
- Characterization and Solid-State Transformations of the Pseudopolymorphic Forms of Sodium NaproxenCrystal Growth & Design, 2004
- EIS investigation of zinc dissolution in aerated sulfate medium. Part I: bulk zincElectrochimica Acta, 2001
- Generation of Gradients Having Complex Shapes Using Microfluidic NetworksAnalytical Chemistry, 2001