Electrochemical sensor based on overoxidized dopamine polymer and 3,4,9,10-perylenetetracarboxylic acid for simultaneous determination of ascorbic acid, dopamine, uric acid, xanthine and hypoxanthine
- 28 August 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (80) , 42632-42637
Abstract
A novel electrode based on 3,4,9,10-perylenetetracarboxylic acid (PTCA) and overoxidized dopamine polymer (PDAox) was developed for the simultaneous determination of ascorbic acid (AA), dopamine (DA), uric acid (UA), xanthine (XN) and hypoxanthine (HXN). The developed sensors exhibited an excellent catalytic activity, high sensitivity and good selectivity toward the oxidation of AA, DA, UA, XN and HXN. Scanning electron microscopy (SEM), cyclic voltammetry (CV), different pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) were employed to characterize the sensor. The peak separations between AA–DA, DA–UA, UA–XN and XN–HXN were large, up to 0.15, 0.18, 0.37 and 0.4 V, respectively. The calibration curves for AA, DA, UA, XN and HXN were obtained in the ranges of 76 μM to 3.9 mM, 0.60 to 253 μM, 1.8 to 238 μM, 5.1 to 289 μM and 3.8 to 293 μM with detection limits (S/N = 3) of 25.3 μM, 0.20 μM, 0.60 μM, 1.7 μM and 1.3 μM, respectively. The integration of PDAox and PTCA in the sensor opens up a facile and promising method for the simultaneous determination of above five substances.Keywords
This publication has 33 references indexed in Scilit:
- Selective and sensitive electrochemical detection of dopamine based on water-soluble porphyrin functionalized graphene nanocompositesRSC Advances, 2014
- Adenosine capped QDs based fluorescent sensor for detection of dopamine with high selectivity and sensitivityThe Analyst, 2013
- Conducting polyaniline-graphene oxide fibrous nanocomposites: preparation, characterization and simultaneous electrochemical detection of ascorbic acid, dopamine and uric acidRSC Advances, 2013
- Nitrogen-doped zinc oxide thin films biosensor for determination of uric acidThe Analyst, 2013
- Simultaneous determination of uric acid, xanthine, hypoxanthine and caffeine in human blood serum and urine samples using electrochemically reduced graphene oxide modified electrodeAnalytica Chimica Acta, 2013
- Poly(3,4-ethylenedioxythiophene)-modified Ni/silicon microchannel plate electrode for the simultaneous determination of ascorbic acid, dopamine and uric acidThe Analyst, 2012
- Simultaneous electrochemical determination of uric acid, xanthine and hypoxanthine based on poly(l-arginine)/graphene composite film modified electrodeTalanta, 2012
- Electrochemical sensor for simultaneous determination of uric acid, xanthine and hypoxanthine based on poly (bromocresol purple) modified glassy carbon electrodeSensors and Actuators B: Chemical, 2010
- Simultaneous electrochemical determination of dopamine, ascorbic acid and uric acid using poly(acid chrome blue K) modified glassy carbon electrodeSensors and Actuators B: Chemical, 2009
- An inlaying ultra-thin carbon paste electrode modified with functional single-wall carbon nanotubes for simultaneous determination of three purine derivativesSensors and Actuators B: Chemical, 2008