Accuracy of the Borg CR10 Scale for Estimating Grip Forces Associated with Hand Tool Tasks
- 18 March 2010
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 7 (5) , 298-306
Abstract
The gripping of tools is required by many industrial operations, and an important aspect of exposure assessment is determining the grip force output of operators. Ratings of perceived exertion can provide an indirect measure of grip force; however, reports in the literature of the use of Borg CR10 scale ratings as a surrogate measure of grip force have been mixed. During a laboratory study with 16 participants, power grip forces were measured directly during three hand tool task simulations: (1) a screwdriver task, (2) a ratchet task, and (3) a lift and carry task, each performed at four force/load levels. Borg scale ratings reported following each trial were compared with mean, peak, and integrated grip forces for the respective trials. Pearson correlations conducted on an individual basis were greatest for the screwdriver task, r∼ 0.9. Correlations for integrated grip force were generally better than for mean or peak force. Correlations were also performed on data pooled for all participants, simulating a cross-sectional sampling approach. Correlations made with pooled data were weaker than when conducted on an individual basis, ranging from r = 0.26 for peak grip force for the lift and carry task, to r = 0.79 for the screwdriver task. When the pooled data were normalized to individual maximum voluntary grip exertions, correlation generally improved but not to the level of the “individually scaled” data. Based on these findings, a protocol is proposed that could improve the strength of correlations between direct measures of grip force and ratings of perceived exertion. Differences in strength of correlation between task simulations are discussed with respect to differences observed in force distributions about the handle for the three tasks.Keywords
This publication has 28 references indexed in Scilit:
- A systematic exploration of distal arm muscle activity and perceived exertion while applying external forces and momentsErgonomics, 2008
- Subjective ratings of upper extremity exposures: Inter-method agreement with direct measurement of exposuresErgonomics, 2008
- Estimation of forces exerted by the fingers using standardised surface electromyography from the forearmErgonomics, 2008
- Prediction of forearm muscle activity during grippingErgonomics, 2006
- Comparison of measurement methods for quantifying hand forceErgonomics, 2005
- Perception of surface pressure applied to the handErgonomics, 1999
- The Strain Index: A Proposed Method to Analyze Jobs For Risk of Distal Upper Extremity DisordersAIHA Journal, 1995
- Evaluation of Grip Force Exertions in Dynamic Manual WorkProceedings of the Human Factors and Ergonomics Society Annual Meeting, 1994
- Assessment of physical work load in epidemiologic studies: concepts, issues and operational considerationsErgonomics, 1994
- Occupational factors and carpal tunnel syndromeAmerican Journal of Industrial Medicine, 1987