Abstract
In this study, a Lyapunov energy function based control method with output voltage feedback loops is proposed for three-phase uninterruptible power supply (UPS) inverters. The presented paper demonstrates that the traditional Lyapunov-energy-function-based control method not only leads to considerable steady-state error in the output voltage, but also distorts the output voltage waveforms. Therefore, a modification has been performed on the traditional Lyapunov-energy-function-based control by incorporating the output voltage feedback loops in the control variables. The robustness of the proposed control method has been studied analytically through transfer functions which are expressed as the ratio of the output voltage to its reference. These analytical results are validated experimentally. In addition, the steady-state and dynamic performances of the proposed control method are also tested experimentally on a three-phase UPS inverter operating with linear (resistive) and nonlinear (diode-bridge rectifier) loads. As a consequence of incorporating output voltage feedback loops into the control variables, the proposed control method offers strong robustness against variations in LC filter parameters, high-quality sinusoidal output voltage along with acceptable total harmonic distortion (THD) values under linear and nonlinear loads, fast dynamic response under abrupt load changes, and negligibly small steady-state error in the output voltage.Keywords
Funding Information
- Qatar National Library
This publication has 27 references indexed in Scilit:
- Deadbeat Control of the Stand-Alone Four-Leg Inverter Considering the Effect of the Neutral Line InductorIEEE Transactions on Industrial Electronics, 2016
- Review: Uninterruptible Power Supply (UPS) systemRenewable and Sustainable Energy Reviews, 2016
- An Observer-Based Optimal Voltage Control Scheme for Three-Phase UPS SystemsIEEE Transactions on Industrial Electronics, 2014
- Model Predictive Approach for a Simple and Effective Load Voltage Control of Four-Leg Inverter With an Output $LC$ FilterIEEE Transactions on Industrial Electronics, 2014
- Flatness-Based Control of Three-Phase Inverter With Output $LC$ FilterIEEE Transactions on Industrial Electronics, 2011
- A Lyapunov-Function-Based Control for a Three-Phase Shunt Hybrid Active FilterIEEE Transactions on Industrial Electronics, 2011
- Model Predictive Control of an Inverter With Output $LC$ Filter for UPS ApplicationsIEEE Transactions on Industrial Electronics, 2009
- An Improved Deadbeat Control for UPS Using Disturbance ObserversIEEE Transactions on Industrial Electronics, 2005
- Lyapunov-based control for three-phase PWM AC/DC voltage-source convertersIEEE Transactions on Power Electronics, 1998
- An elementary proof of Kharitonov's stability theorem with extensionsIEEE Transactions on Automatic Control, 1989