Bias Atlases for Segmentation-Based PET Attenuation Correction Using PET-CT and MR
- 16 September 2013
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 60 (5) , 3373-3382
Abstract
This study was to obtain voxel-wise PET accuracy and precision using tissue-segmentation for attenuation correction. We applied multiple thresholds to the CTs of 23 patients to classify tissues. For six of the 23 patients, MR images were also acquired. The MR fat/in-phase ratio images were used for fat segmentation. Segmented tissue classes were used to create attenuation maps, which were used for attenuation correction in PET reconstruction. PET bias images were then computed using the PET reconstructed with the original CT as the reference. We registered the CTs for all the patients and transformed the corresponding bias images accordingly. We then obtained the mean and standard deviation bias atlas using all the registered bias images. Our CT-based study shows that four-class segmentation (air, lungs, fat, other tissues), which is available on most PET-MR scanners, yields 15.1%, 4.1%, 6.6%, and 12.9% RMSE bias in lungs, fat, non-fat soft-tissues, and bones, respectively. An accurate fat identification is achievable using fat/in-phase MR images. Furthermore, we have found that three-class segmentation (air, lungs, other tissues) yields less than 5% standard deviation of bias within the heart, liver, and kidneys. This implies that three-class segmentation can be sufficient to achieve small variation of bias for imaging these three organs. Finally, we have found that inter- and intra-patient lung density variations contribute almost equally to the overall standard deviation of bias within the lungs.Keywords
This publication has 33 references indexed in Scilit:
- Challenges and current methods for attenuation correction in PET/MRMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Three-region MRI-based whole-body attenuation correction for automated PET reconstructionNuclear Medicine and Biology, 2010
- MR-based attenuation correction for a whole-body sequential PET/MR system2009
- Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT DataJournal of Nuclear Medicine, 2009
- A Simple Regularizer for B-spline Nonrigid Image Registration That Encourages Local InvertibilityIEEE Journal of Selected Topics in Signal Processing, 2009
- Strategies for attenuation compensation in neurological PET studiesNeuroImage, 2007
- A generalized model for the conversion from CT numbers to linear attenuation coefficientsIEEE Transactions on Nuclear Science, 2003
- Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomographyMedical Physics, 2003
- Optimization of mutual information for multiresolution image registrationIEEE Transactions on Image Processing, 2000
- Segmented MR images for brain attenuation correction in PET1994