The effect of bronchoscopic lung volume reduction on the bronchodilator response
Authors:
Open Access
- 1 October 2024
- journal article
- research article
- Published by AME Publishing Company in Journal of Thoracic Disease
- Vol. 16 (10) , 6820-6826
Abstract
Background: Bronchoscopic lung volume reduction (BLVR) is a method of achieving lung collapse in severely emphysematous regions. One of the measures of success is the improvement in post-bronchodilator forced expiratory volume in the first second (FEV1). The change in bronchodilator response (BDR) following BLVR is typically not reported, however, the changes in lung physiology that accompany endobronchial valve placement may impact aerosol drug delivery and alter the response to bronchodilators. We compared the BDR before and after BLVR to evaluate this effect. Methods: We performed a retrospective study to analyze the change in BDR following BLVR. We included patients who underwent pulmonary function test (PFT) within 6 months of BLVR and confirmed complete lobar atelectasis. The pre-BLVR BDR for each patient served as the control, which was then compared to the post-BLVR BDR. The mean difference in the BDR before and after valve placement was determined. The comparison between pre- and post-BLVR means was performed using a t-test. Results: A total of 35 patients were assessed for the study. Fifteen patients were excluded (due to valve removal, incomplete lobar collapse, and no pre- or post-BLVR PFT available). Of the 20 remaining patients, 14 had a positive BDR at baseline before BLVR. Following BLVR, 13 of the 14 patients demonstrated a non-significant increase in the BDR. The mean BDR for pre- and post-valve was 83.6 vs. 116.3 mL, respectively. The mean absolute increase in BDR following BLVR was 32.7 mL [95% confidence interval (CI): −32.5 to 97.8, P=0.31]. When including all 20 patients, the mean BDR pre- and post-BLVR was 47.5 vs. 86.5 mL, respectively, with a mean increase in BDR by 39 mL (95% CI: 22.3 to 100.3, P=0.21). Conclusions: BLVR may improve the BDR in patients with complete lobar atelectasis.Keywords
This publication has 16 references indexed in Scilit:
- Improving Lung Function in Severe Heterogenous Emphysema with the Spiration Valve System (EMPROVE). A Multicenter, Open-Label Randomized Controlled Clinical TrialAmerican Journal of Respiratory and Critical Care Medicine, 2019
- The REACH Trial: A Randomized Controlled Trial Assessing the Safety and Effectiveness of the Spiration® Valve System in the Treatment of Severe EmphysemaRespiration, 2018
- Bronchoscopic lung volume reduction procedures for chronic obstructive pulmonary diseaseCochrane Database of Systematic Reviews, 2017
- Distribution of aerosolized particles in healthy and emphysematous rat lungs: Comparison between experimental and numerical studiesJournal of Biomechanics, 2015
- Mechanisms of Pharmaceutical Aerosol Deposition in the Respiratory TractAAPS PharmSciTech, 2014
- Pathogenesis of hyperinflation in chronic obstructive pulmonary diseaseInternational Journal of Chronic Obstructive Pulmonary Disease, 2014
- Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysemaJournal of Applied Physiology, 2013
- Physiologic Basis for Improved Pulmonary Function after Lung Volume ReductionProceedings of the American Thoracic Society, 2008
- Pulmonary drug delivery. Part I: Physiological factors affecting therapeutic effectiveness of aerosolized medicationsBritish Journal of Clinical Pharmacology, 2003
- AUTORADIOGRAPHIC VISUALIZATION OF BETA-ADRENOCEPTOR SUBTYPES IN HUMAN-LUNG1985