Semiautomated intraocular laser surgery using handheld instruments
- 23 March 2010
- journal article
- case report
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 42 (3) , 264-273
Abstract
Background and Objective In laser retinal photocoagulation, hundreds of dot‐like burns are applied. We introduce a robot‐assisted technique to enhance the accuracy and reduce the tedium of the procedure. Materials and Methods Laser burn locations are overlaid on preoperative retinal images using common patterns such as grids. A stereo camera/monitor setup registers and displays the planned burn locations overlaid on real‐time video. Using an active handheld micromanipulator, a 7 × 7 grid of burns spaced 650 µm apart is applied to both paper slides and porcine retina in vitro using 30 millisecomds laser pulses at 532 nm. Two scenarios were tested: unaided, in which the micromanipulator is inert and the laser fires at a fixed frequency, and aided, in which the micromanipulator actively targets burn locations and the laser fires automatically upon target acquisition. Error is defined as the distance from the center of the observed burn mark to the preoperatively selected target location. Results An experienced retinal surgeon performed trials with and without robotic assistance, on both paper slides and porcine retina in vitro. In the paper slide experiments at an unaided laser repeat rate of 0.5 Hz, error was 125±62 µm with robotic assistance and 149±76 µm without (P < 0.005), and trial duration was 70±8 seconds with robotic assistance and 97±7 seconds without (P < 0.005). At a repeat rate of 1.0 Hz, error was 129±69 µm with robotic assistance and 166±91 µm without (P < 0.005), and trial duration was 26±4 seconds with robotic assistance and 47±1 seconds without (P < 0.005). At a repeat rate of 2.0 Hz on porcine retinal tissue, error was 123±69 µm with robotic assistance and 203±104 µm without (P < 0.005). Conclusion Robotic assistance can increase the accuracy of laser photocoagulation while reducing the duration of the operation. Lasers Surg. Med. 42:264–273, 2010.Keywords
This publication has 28 references indexed in Scilit:
- Micropulse diode laser photocoagulation for central serous chorio‐retinopathyClinical & Experimental Ophthalmology, 2009
- A Randomized Trial Comparing the Efficacy and Safety of Intravitreal Triamcinolone With Standard Care to Treat Vision Loss Associated With Macular Edema Secondary to Branch Retinal Vein OcclusionArchives of Ophthalmology (1950), 2009
- Efficacy of patterned scan laser in treatment of macular edema and retinal neovascularizationClinical Ophthalmology, 2009
- Review of the Ocular Angiogenesis Animal ModelsSeminars in Ophthalmology, 2009
- A Randomized Trial Comparing Intravitreal Triamcinolone Acetonide and Focal/Grid Photocoagulation for Diabetic Macular EdemaOphthalmology, 2008
- Initial experience with the Pascal photocoagulator: a pilot study of 75 proceduresBritish Journal of Ophthalmology, 2008
- Toward active tremor canceling in handheld microsurgical instrumentsIEEE Transactions on Robotics and Automation, 2003
- Recent progress in coded structured light as a technique to solve the correspondence problemPattern Recognition, 1998
- SURGICAL MANAGEMENT OF INTRARETINAL FOREIGN BODIESRetina, 1994
- Argon laser photocoagulation in the treatment of central serous retinopathy.British Journal of Ophthalmology, 1979