Chip based common-path optical coherence tomography system with an on-chip microlens and multi-reference suppression algorithm
Open Access
- 1 June 2016
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 24 (12) , 12635-12650
Abstract
We demonstrate an integrated optical probe including an on-chip microlens for a common-path swept-source optical coherence tomography system. This common-path design uses the end facet of the silicon oxynitride waveguide as the reference plane, thus eliminating the need of a space-consuming and dispersive on-chip loop reference arm, thereby obviating the need for dispersion compensation. The on-chip micro-ball lens eliminates the need of external optical elements for coupling the light between the chip and the sample. The use of this lens leads to a signal enhancement up to 37 dB compared to the chip without a lens. The light source, the common-path arm and the detector are connected by a symmetric Y junction having a wavelength independent splitting ratio (50/50) over a much larger bandwidth than can be obtained with a directional coupler. The signal-to-noise ratio of the system was measured to be 71 dB with 2.6 mW of power on a mirror sample at a distance of 0.3 mm from the waveguide end facet. Cross-sectional OCT images of a layered optical phantom sample are demonstrated with our system. A method, based on an extended Fourier-domain OCT model, for suppressing ghost images caused by additional parasitic reference planes is experimentally demonstrated.Keywords
Funding Information
- Technology Foundation RVO (IOP PD100019)
This publication has 32 references indexed in Scilit:
- Miniature spectrometer and beam splitter for an optical coherence tomography on a silicon chipOptics Express, 2013
- OCT for industrial applications2012
- Optical coherence tomography – development, principles, applicationsZeitschrift für Medizinische Physik, 2010
- High-speed optical coherence tomography: basics and applicationsApplied Optics, 2010
- Beyond biomedicine: a review of alternative applications and developments for optical coherence tomographyApplied Physics B, 2007
- Surface inspection of hard to reach industrial parts using low-coherence interferometry2006
- Novel noncontact thickness metrology for backend manufacturing of wide bandgap light emitting devicesphysica status solidi (c), 2005
- Low-coherence interferometric absolute distance gauge for study of MEMS structures2005
- Sensitivity advantage of swept source and Fourier domain optical coherence tomographyOptics Express, 2003
- Optical Coherence TomographyScience, 1991