Standardization of Muscle Palpation— Methodological Considerations
- 1 February 2014
- journal article
- research article
- Published by Wolters Kluwer Health in The Clinical Journal of Pain
- Vol. 30 (2) , 174-182
Abstract
Objectives: To compare test-retest variability of palpation between a new palpometer and manual palpation using (1) right or left hand, (2) index or middle finger, (3) randomized or fixed sequence of force levels, (4) palpation on soft or hard surface, and (5) palpation for 2 or 10 seconds. Methods: Twelve clinicians were instructed to target 0.5, 1.0, and 2.0 kg on a force meter using a palpometer (adjustable spring-coil with a small pin touching the examiner’s hand when the correct pressure is achieved) and manual palpation with right or left hand, index or middle finger, randomized or fixed sequence of force levels, on hard or soft surface, and for 2 or 10 seconds. During all experiments, 10 force measures were taken and variability was determined as coefficient of variation (CV) and compared with analyses of variance. Results: In all experiments, the palpometer had lower variability compared with manual palpation (PP=0.122), index and middle finger (P=0.240), and soft and hard surface (P=0.240). Random sequence of force levels had higher CVs than fixed sequence with manual palpation (P=0.004), but not with palpometer (P=0.856). CVs for 2 seconds palpation were higher than 10 seconds (P=0.002). Conclusions: The palpometer had low test-retest variability and provided a more accurate and reproducible pressure stimulus than manual palpation. The findings of this study may help to standardize palpation of human muscles required for accurate and reliable diagnosis of musculoskeletal pain conditions.Keywords
This publication has 7 references indexed in Scilit:
- Etiology of Myofascial Trigger PointsCurrent Pain and Headache Reports, 2012
- Computer‐controlled pneumatic pressure algometry—a new technique for quantitative sensory testingEuropean journal of pain, 2001
- Reproducibility of examiner performance for muscle and joint palpation in the temporomandibular system following training and calibrationCommunity Dentistry and Oral Epidemiology, 1993
- Evaluation of Pressure Pain Threshold in Head and Neck Muscles by Electronic Algometer: Intrarater and Interrater ReliabilityCranio®, 1992
- Pressure pain thresholds, clinical assessment, and differential diagnosis: reliability and validity in patients with myogenic painPain, 1989
- Reliability of the pressure algometer as a measure of myofascial trigger point sensitivityPain, 1986
- A Prevalence Study of the Clinical Signs Associated with Mandibular DysfunctionThe Journal of the American Dental Association, 1983