Biomechanical Corneal Parameters in Eyes With Chronic Ocular Hypotony and in Non-Hypotonic Eyes. Self-Controlled Case Series Study
Authors:
- Rachid Bouchikh-El JarroudiRJRachid Bouchikh-El Jarroudi
- Kolbe Roche FernándezKFKolbe Roche Fernández
- Pau Romera RomeroPRPau Romera Romero
- Tatiana Croitoru-CroitoruTCTatiana Croitoru-Croitoru
- Anna Goñi-GuarroAGAnna Goñi-Guarro
- Jessica Botella-GarciaJBJessica Botella-Garcia
- Jordi Loscos-ArenasJLJordi Loscos-Arenas
- Sebastian VidelaSVSebastian Videla
Open Access
- 1 April 2025
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 1237-1246
Abstract
Introduction: There are no available data concerning corneal parameters in patients with chronic ocular hypotony. Our purpose is to provide evidence and clinical correlation on the biomechanical corneal changes in chronic hypotonic eyes. Patients and Methods: A single-center, transversal, self-controlled case series study was conducted involving patients with at least one chronic hypotonic eye (defined as an intraocular pressure ≤ 6.5 mmHg measured on three separate occasions for at least three months). The chronic hypotonic eye was the case and the contralateral eye the control (non-hypotonic eye). We collected data from baseline characteristic and intraocular pressure (mmHg). Biomechanical corneal parameters measured by Corvis ST: deformation amplitude ratio (mm), Ambrósio’s relational thickness (μm), stiffness parameter at first applanation (mmHg/mm), Integrated radius (mm− 1), stress-strain index, pachymetry (μm), and in addition macular folds were recorded as well. A descriptive and exploratory analysis was performed. Results: Between November 2021 and July 2023, a total of 16 consecutive patients (7 men, 9 women; age [median (range)]: 72 (62– 84)), diagnosed with chronic ocular hypotony in one eye were included: 16 chronic hypotonic eyes and 16 non-hypotonic eyes. Hypotonic versus non-hypotonic eyes [median (range)]: intraocular pressure: 4 (2– 6) mmHg, 16 (8– 38) mmHg; deformation amplitude ratio: 5.6 (4.3– 6.6) mm, 4.7 (3.9– 5.5) mm, p-value= 0.002; Ambrósio’s relational thickness: 482 (263– 932) μm, 530 (210– 818) μm, p-value: 0.845; stiffness parameter at first applanation: 61.5 (39– 100) mmHg/mm, 113 (68– 130) mmHg/mm, p-value: < 0.001; Integrated radius: 10.9 mm− 1 (6.3– 16.8), 7.9 mm− 1 (6.4– 10.5), p-value: < 0.001; stress-strain index: 0.7 (− 0.2– 4.9), 1.1 (− 2.7– 5.6), p-value: 0.034; pachymetry 509 (456– 617) μm, 512 (436– 775) μm, p-value: 0.637; and macular folds: 7/16, 0/16, p-value: < 0.001. Conclusions: Chronic hypotonic eyes (eyes with a low intraocular pressure) present biomechanical corneal changes with respect to non-hypotonic eyes, mainly in deformation amplitude ratio, stiffness parameter at first applanation, stress-strain index and Ambrósio’s relational thickness parameters. These biomechanical corneal changes could reflect softer, more elastic and deformable scleras, which at its turn can bear higher risk of hypotony maculopathy.Keywords
This publication has 27 references indexed in Scilit:
- Factors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug AnalyzerInvestigative Ophthalmology & Visual Science, 2017
- A New Tonometer—The Corvis ST Tonometer: Clinical Comparison with Noncontact and Goldmann Applanation TonometersInvestigative Ophthalmology & Visual Science, 2013
- Ocular Response AnalyzerJournal of Current Glaucoma Practice, 2012
- What Biomechanical Properties of the Cornea Are Relevant for the Clinician?Survey of Ophthalmology, 2007
- Hypotony maculopathyActa Ophthalmologica Scandinavica, 2007
- Corneal structure and biomechanics: impact on the diagnosis and management of glaucomaCurrent Opinion in Ophthalmology, 2006
- Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma DamageAmerican Journal of Ophthalmology, 2006
- Role of the sclera in the development and pathological complications of myopiaProgress in Retinal and Eye Research, 2003
- Prevention and Management of Hypotony After Glaucoma SurgeryInternational Ophthalmology Clinics, 1999
- AQUEOUS-HUMOR DYNAMICS IN EXPERIMENTAL IRIDOCYCLITIS1987