Experimental and Theoretical Analysis of Tubular Membrane Aeration for Mammalian Cell Bioreactors
- 5 September 2008
- journal article
- research article
- Published by Wiley in Biotechnology Progress
- Vol. 19 (4) , 1183-1189
Abstract
A combination of experimental and theoretical approaches was used to characterize the dynamics of oxygen transfer in a membrane‐aerated bioreactor. Pressure profiles along the length of the membrane at varying entrance and exit pressures were determined by actual experimental measurements, unlike most previous studies that have relied solely on theoretical descriptions of the pressure profile in the tubing. The mass transfer coefficient, kLa, was also determined under these conditions and was found to be essentially independent of tubing exit pressure. Measurement of the tubing pressure profile coupled with estimation of kLa allowed for computation of the oxygen transfer rate (OTR) along the length of the tubing. A mathematical model that incorporated friction pressure loss and losses due to tubing bending was developed to describe the pressure and hence OTR characteristics of membrane‐aerated systems. The applicability of the model was verified by testing it on experimentally measured pressure data, and in all cases the model accurately described experimental data. When tubing properties are known, the mathematical model presented in this study allows for a priori estimation of OTR profiles along the length of the tubing. This information is vital for optimal design and scale‐up of membrane‐aerated bioreactors for mammalian cell culture.Keywords
This publication has 15 references indexed in Scilit:
- Bubble-free oxygenation by means of hydrophobic porous membranesEnzyme and Microbial Technology, 1995
- Monoclonal antibody productivity and the metabolic pattern of perfusion cultures under varying oxygen tensionsBiotechnology and Bioengineering, 1993
- The use of independently sealed microporous hollow fiber membranes for oxygenation of water: model developmentJournal of Membrane Science, 1992
- Use of sealed end hollow fibers for bubbleless membrane aeration: experimental studiesJournal of Membrane Science, 1992
- Optimal Design of the Tubular Microporous Membrane Aerator for Shear‐Sensitive Cell CulturesBiotechnology Progress, 1992
- Effects of Dissolved Oxygen on Hybridoma Cell Growth, Metabolism, and Antibody Production Kinetics in Continuous CultureBiotechnology Progress, 1990
- Relationship between oxygen consumption rate and cellular activity of mammalian cells cultured in serum‐free mediaBiotechnology and Bioengineering, 1990
- Bubble-free aeration using membranes: mass transfer analysisJournal of Membrane Science, 1989
- Scale‐up of bioreactors for fermentation of mammalian cell cultures with special reference to oxygen supply and microcarrier mixingChemical Engineering & Technology, 1988
- Effects of dissolved oxygen concentration on hybridoma growth and metabolism in continuous cultureJournal of Cellular Physiology, 1987