A theoretical high-density nanoscopy study leads to the design of UNLOC, an unsupervised algorithm
Authors:
- Sébastien MailfertSMSébastien Mailfert
- Jérôme TouvierJTJérôme Touvier
- Lamia BenyoussefLBLamia Benyoussef
- Roxane FabreRFRoxane Fabre
- Asma RabaouiARAsma Rabaoui
- Marie-Claire BlacheMBMarie-Claire Blache
- Yannick HamonYHYannick Hamon
- Sophie BrustleinSBSophie Brustlein
- Serge MonneretSMSerge Monneret
- Didier Albert MarguetDMDidier Albert Marguet
- Nicolas BertauxNBNicolas Bertaux
Preprint
Abstract
Among the superresolution microscopy techniques, the ones based on serially imaging sparse fluorescent particles enable the reconstruction of high-resolution images by localizing single molecules. Although challenging, single-molecule localization microscopy (SMLM) methods aim at listing the position of individual molecules leading a proper quantification of the stoichiometry and spatial organization of molecular actors. However, reaching the precision requested to localize accurately single molecules is mainly constrained by the signal-to-noise ratio (SNR) but also the density ( D frame ), i.e., the number of fluorescent particles per μm 2 per frame. Of central interest, we establish here a comprehensive theoretical study relying on both SNR and D frame to delineate the achievable limits for accurate SMLM observations. We demonstrate that, for low-density hypothesis (i.e. one-Gaussian fitting hypothesis), any fluorescent particle biases the localization of a particle of interest when they are distant by less than ≈ 600 nm. Unexpectedly, we also report that even dim fluorescent particles should be taken into account to ascertain unbiased localization of any surrounding particles. Therefore, increased D frame quickly deteriorates the localization precision, the image reconstruction and more generally the quantification accuracy. The first outcome is a standardized density-SNR space diagram to determine the achievable SMLM resolution expected with experimental data. Additionally, this study leads to the identification of the essential requirements for implementing UNLOC (UNsupervised particle LOCalization), an unsupervised and fast computing algorithm approaching the Cramér-Rao bound for particles at high-density per frame and without any prior on their intensity. UNLOC is available as an ImageJ plugin.Keywords
All Related Versions
- Published version: Biophysical Journal, 115 (3), 565.
This publication has 42 references indexed in Scilit:
- Statistical Deconvolution for Superresolution Fluorescence MicroscopyBiophysical Journal, 2012
- Faster STORM using compressed sensingNature Methods, 2012
- Dual-objective STORM reveals three-dimensional filament organization in the actin cytoskeletonNature Methods, 2012
- Bayesian localization microscopy reveals nanoscale podosome dynamicsNature Methods, 2011
- Optimized localization analysis for single-molecule tracking and super-resolution microscopyNature Methods, 2010
- Fast, background-free, 3D super-resolution optical fluctuation imaging (SOFI)Proceedings of the National Academy of Sciences, 2009
- Wide-field subdiffraction imaging by accumulated binding of diffusing probesProceedings of the National Academy of Sciences, 2006
- Imaging Intracellular Fluorescent Proteins at Nanometer ResolutionScience, 2006
- Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)Nature Methods, 2006