Multi-commutation flow system with on-line solid phase extraction exploiting the ion-imprinted polymer and FAAS detection for chromium speciation analysis in sewage samples
- 23 December 2014
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (4) , 1517-1526
Abstract
A multi-commutation flow analysis system using on-line solid phase extraction and flame atomic absorption spectrometric detection (MCFA-FAAS) was developed for the study of chromium speciation in sewage samples. A new chromium imprinted polymer was prepared and applied as a selective sorbent for the separation and preconcentration of Cr(III) ions. The polymer was prepared using a Cr(III)-8-hydroxyquinoline complex as a template, styrene as a functional monomer, and divinylbenzene as a crosslinking monomer using 2,2′- azobisisobutyronitrile as an radical initiator for bulk polymerization. The chromium imprinted polymer exhibits good chemical and mechanical stability, sorption capacity and selectivity towards Cr(III) ions. The analyte, Cr(III) ions, was quantitatively retained on the sorbent at pH 9, eluted with 0.3 mL of 0.1 mol L−1 nitric acid and determined by FAAS with a detection limit of 2.1 ng mL−1 and a 33-fold preconcentration factor obtained with a 10 min loading time. The MCFA-FAAS system is fully automated and enables analysis of 1 mL of sample in 4.5 min, which gives a throughput of 12 samples per hour. The accuracy of the proposed method was proved by analysis of a reference material of wastewater RES 10.2 (ielab). The method was successfully applied to the determination of trace amounts of Cr(III) in municipal sewage samples.Keywords
This publication has 30 references indexed in Scilit:
- Modified mesoporous silica materials for on-line separation and preconcentration of hexavalent chromium using a microcolumn coupled with flame atomic absorption spectrometryAnalytica Chimica Acta, 2012
- Application of graphene as a sorbent for preconcentration and determination of trace amounts of chromium(III) in water samples by flame atomic absorption spectrometryAnalytical Methods, 2012
- A new chelating resin: Synthesis, characterization and application for speciation of chromium (III)/(VI) speciesChemical Engineering Journal, 2012
- Speciation of Cr(III) and Cr(VI) in geological and water samples by ytterbium(III) hydroxide coprecipitation system and atomic absorption spectrometryFood and Chemical Toxicology, 2011
- Ionic liquid as a complexation and extraction medium combined with high-performance liquid chromatography in the evaluation of chromium(VI) and chromium(III) speciation in wastewater samplesMicrochemical Journal, 2011
- Extractive separation and determination of chromium in tannery effluents and electroplating waste water using tribenzylamine as the extractantJournal of Hazardous Materials, 2009
- Speciation of Cr(III) and Cr(VI) in environmental samples determined by selective separation and preconcentration on silica gel chemically modified with niobium(V) oxideJournal of Hazardous Materials, 2009
- A novel solid phase extraction procedure on Amberlite XAD-1180 for speciation of Cr(III), Cr(VI) and total chromium in environmental and pharmaceutical samplesJournal of Hazardous Materials, 2008
- Determination of chromium(VI) and lead in water samples by on-line sorption preconcentration coupled with flame atomic absorption spectrometry using a PCTFE-beads packed columnTalanta, 2007
- Speciation of hexavalent chromium in waters by liquid–liquid extraction and GFAAS determinationMicrochemical Journal, 2007