Biomechanical Evaluation of the Vertebral Jack Tool and the Inflatable Bone Tamp for Reduction of Osteoporotic Spine Fractures
- 15 August 2009
- journal article
- biomechanics
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (18) , E640-E644
Abstract
Study Design. Controlled in vitro study. Objective. To compare two kyphoplasty techniques in cadaveric fractured vertebrae: an experimental vertebral jack tool (VJT) and an inflatable bone tamp (IBT). Summary of Background Data. A previous biomechanical study showed restored strength and stiffness after height restoration in cadaveric-fractured osteoporotic vertebrae using a new device for reduction of osteoporotic vertebral fractures. Methods. Anterior wedge fractures (AO type A1.2) were created in 8 (4 lumbar, 4 thoracic) vertebrae by displacement eccentric external forces. In all vertebrae the amount of height reduction was 35%. After compression, 4 vertebrae were restored in height using the VJT procedure. Four vertebrae were restored in height using the IBT procedure. Posttreatment strength and stiffness of the vertebrae were determined by a compression test identical to the pretreatment compression protocol. Results. In the VJT group the postrestoration strength was 81% ± 13% of the original strength and in the IBT group it was 96% ± 32%. The postrestoration stiffness in the VJT group was 61% ± 42% of the original stiffness and in the IBT group 76% ± 62% of the original stiffness. The vertebrae in the VJT group were restored to 101% ± 2% of their original height whereas this was 104% ± 14% in the IBT group. In this study, no cases of cement leakage were found. No cases of damaging of the end plates, new fractures or perforations were seen in both groups. The mean amount of cement inserted for the VJT group was 3.6 ± 0.9 cm3 and for the IBT group 5.9 ± 0.8 cm3. Conclusion. Both kyphoplasty procedures were able to restore height in this in vitro study, while strength and stiffness were partially restored, with no significant differences. In this study on average significant less cement was used in the VJT procedure. No complications were noted in both groups. This new end plate-to-end plate laminar augmentation technique may be of clinical advantage.Keywords
This publication has 34 references indexed in Scilit:
- Percutaneous vertebroplasty as a treatment for osteoporotic vertebral compression fractures: a systematic reviewEuropean Spine Journal, 2006
- Treatment of Painful Vertebral Fractures by Kyphoplasty in Patients With Primary Osteoporosis: A Prospective Nonrandomized Controlled StudyJournal of Bone and Mineral Research, 2005
- A Review of Complications Associated with Vertebroplasty and Kyphoplasty as Reported to the Food and Drug Administration Medical Device Related Web SiteJournal of Vascular and Interventional Radiology, 2004
- Complications of percutaneous vertebroplasty and their preventionSkeletal Radiology, 2004
- An Ex Vivo Evaluation of an Inflatable Bone Tamp Used to Reduce Fractures Within Vertebral Bodies Under LoadSpine, 2002
- An Ex Vivo Biomechanical Evaluation of an Inflatable Bone Tamp Used in the Treatment of Compression FractureSpine, 2001
- Consequences of Vertebral Deformities in Older Men and WomenJournal of Bone and Mineral Research, 2000
- Reduced Pulmonary Function in Patients with Spinal Osteoporotic FracturesOsteoporosis International, 1998
- Vertebral Deformities and Functional Impairment in Men and WomenJournal of Bone and Mineral Research, 1997
- Association of osteoporotic vertebral compression fractures with impaired functional statusThe American Journal of Medicine, 1993