At part load conditions, Francis turbines experience the formation of a cavitation vortex rope at the runner outlet whose precession acts as a pressure excitation source for the hydraulic circuit. This can lead to hydro-acoustic resonances characterized by high pressure pulsations, as well as torque and output power fluctuations. This study highlights the influence of the discharge factor on both the vortex parameters and the pressure excitation source by performing Particle Image Velocimetry (PIV) and pressure measurements. Moreover, it is shown that the occurrence of hydro-acoustic resonances in cavitation conditions mainly depend on the swirl degree of the flow independently of the speed factor. Empirical laws linking both natural and precession frequencies with the operating parameters of the machine are, then, derived, enabling the prediction of resonance conditions on the complete part load operating range of the turbine.Keywords
This publication has 6 references indexed in Scilit:
- LDV survey of cavitation and resonance effect on the precessing vortex rope dynamics in the draft tube of Francis turbinesExperiments in Fluids, 2016
- Local wave speed and bulk flow viscosity in Francis turbines at part load operationJournal of Hydraulic Research, 2016
- Study of the vortex-induced pressure excitation source in a Francis turbine draft tube by particle image velocimetryExperiments in Fluids, 2015
- Draft tube discharge fluctuation during self-sustained pressure surge: fluorescent particle image velocimetry in two-phase flowExperiments in Fluids, 2013
- Combining PIV, POD and vortex identification algorithms for the study of unsteady turbulent swirling flowsMeasurement Science and Technology, 2001
- Dynamics of the cavitation precessing vortex rope for Francis turbines at part load operating conditions