Initial Experience in Transvenous Implantation of a Left Ventricular Lead With a Novel Venogram Balloon Catheter
Authors:
Open Access
- 30 June 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 892122
Abstract
Aim: The most challenging and time-consuming stage of cardiac resynchronization therapy (CRT) device implantation is coronary sinus (CS) cannulation and left ventricular epicardial electrode implantation. This paper reports the initial clinical experience of CS cannulation and left ventricular lead implantation guided by a novel venogram balloon catheter (Lee’s venogram balloon catheter).Methods and Results: Consecutive patients eligible for CRT were deemed suitable for this novel venogram balloon catheter. Parameters such as left ventricular lead implantation time, procedure time, and fluoroscopy time were recorded. CS cannulation with LV lead implantation guided by Lee’s venogram balloon catheter was successful in all 5 patients, including 4 challenging cases. The total fluoroscopy and procedural durations were 5.0 ± 3.0 and 57.4 ± 12.5 min, respectively. No adverse catheter-related events occurred during the procedures.Conclusion: This initial study of an innovative venogram balloon catheter demonstrated that it greatly facilitated CS cannulation and successful LV lead placement in all patients undergoing CRT system implantation. This significantly shortened the learning curve and showed a decrease in left ventricular lead implantation time, procedure time, and fluoroscopy time.Keywords
This publication has 6 references indexed in Scilit:
- The combination of coronary sinus ostial atresia/abnormalities and a small persistent left superior vena cava—Opportunity for left ventricular lead implantation and unrecognized source of thromboembolic strokeHeart Rhythm, 2021
- Interventional device implantation, Part I: Basic techniques to avoid complications: A hands‐on approachJournal of Cardiovascular Electrophysiology, 2020
- Challenges and Solutions for Difficult Implantations of CRT Devices: The Role of New Technology and TechniquesJournal of Cardiovascular Electrophysiology, 2006
- Cardiac Resynchronization TherapyJACC, 2005
- Double Wire Technique to Catheterize Sharply Angulated Coronary Sinus Branches in Cardiac Resynchronization TherapyPacing and Clinical Electrophysiology, 2005
- Technical considerations in implanting left ventricular pacing leads for cardiac resynchronisation therapyEuropean Heart Journal Supplements, 2004