Insulin Pump Failures: Has There Been an Improvement? Update of a Prospective Observational Study
- 1 December 2016
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 18 (12) , 820-824
Abstract
Background: Insulin pump failures had been assessed in our center by a prospective observational study from 2001 to 2007. The aim of this study was to update our data since 2008 and to determine whether there exist specific risk factors for insulin pump failures. Methods: All insulin pump defects were prospectively collected between 2008 and 2013 in a monocentric cohort of 350 new pumps. Clinical consequences were recorded. Brand and model of pumps and type of defects and patients' characteristics (gender, type of diabetes, age at diabetes diagnosis, age at first pump, pump treatment duration, number of previous pumps, and number of previous pump failures) were tested for possible association with insulin pump failure. Results: Malfunctions occurred in 239 (68%) pumps. The incidence rate was 33/100 pump-years. There were 28 (12%) complete failures, 17 (7%) alarms, 83 (35%) mechanical defects, and 105 (44%) minor defects. Survival curves did not differ according to pump brand and model. Hyperglycemia occurred in 2.9% of cases. In multivariate analysis, only patient age less than 40 years at the initiation of pump therapy was associated with higher risk of malfunction (hazard ratio 1.64; 95% confidence interval 1.19–2.24; P = 0.002). Conclusions: Pump malfunctions remain common with modern pumps. We report less complete failures than in our previous study. This could be because of improvement in quality of pumps or to our strategy of systematic screening and replacement in case of mechanical defects.Keywords
This publication has 12 references indexed in Scilit:
- Continuous subcutaneous insulin infusion in diabetes: patient populations, safety, efficacy, and pharmacoeconomicsDiabetes/Metabolism Research and Reviews, 2015
- Insulin pump risks and benefits: a clinical appraisal of pump safety standards, adverse event reporting and research needs. A Joint Statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working GroupDiabetologia, 2015
- Impact of new technologies on diabetes careWorld Journal of Diabetes, 2015
- Insulin Pump–Associated Adverse Events in Children and Adolescents—A Prospective StudyDiabetes Technology & Therapeutics, 2014
- Nonmetabolic Complications of Continuous Subcutaneous Insulin Infusion: A Patient SurveyDiabetes Technology & Therapeutics, 2014
- Insulin Pump Therapy in Children with Type 1 Diabetes: the Dark Side of the MoonJournal of Diabetes Science and Technology, 2013
- Insulin pump failures are still frequent: a prospective study over 6 years from 2001 to 2007Diabetologia, 2009
- Adolescent Use of Insulin and Patient-Controlled Analgesia Pump Technology: A 10-Year Food and Drug Administration Retrospective Study of Adverse EventsPediatrics, 2008
- Technical risks with subcutaneous insulin infusionDiabetes & Metabolism, 2006
- Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.BMJ, 1978