The Pocket Echocardiograph: A Pilot Study of Its Validation and Feasibility in Intubated Patients
- 17 February 2011
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 28 (4) , 371-377
Abstract
The clinical use of miniaturized echocardiograph devices is expanding due to the potential to rapidly assess cardiac function in the critically ill patient. Novice echocardiographers have used the pocket echocardiograph (PE) to estimate ejection fraction in ambulatory patients, but have not evaluated intubated patients. We hypothesize that a novice echocardiographer can use PE to acquire interpretable cardiac images, and provide an accurate tool for estimating ejection fraction. Subjects scheduled for cardiac surgery underwent blinded transesophageal echocardiography (TEE) and PE during a hemodynamically stable period after endotracheal intubation prior to incision. A single cardiology fellow acquired all PE images. The fellow and an experienced echocardiographer interpreted PE studies offline in a blinded fashion, visually estimating ejection fraction and assigning an image quality grade. Comparisons were made to the TEE study. Subjects (n = 22) were 81% male; age 69 ± 9 years, and had a mean ejection fraction of 51% ± 10.0%. Parasternal images were adequate in the vast majority of patients (77%), limited in 14%, and unacceptable in 9%, while apical (41%, 45%, and 14%) and subcostal (36%, 32%, and 32%) image quality was inferior. Ejection fraction showed fair correlation, bias, and limits of agreement for the fellow's interpretation (r = 0.50, 4.9%, ± 20.7%), with stronger association for the experienced echocardiographer (r = 0.76, 3.3%, ± 16.6%). A novice echocardiographer using PE can acquire interpretable images in the majority of intubated patients. Novice and expert echocardiographers can reasonably estimate ejection fraction using PE. PE may allow novice echocardiographers to rapidly assess cardiac function in intubated patients.Keywords
This publication has 18 references indexed in Scilit:
- Hand-carried echocardiography for assessment of left ventricular filling and ejection fraction in the surgical intensive care unitJournal of Critical Care, 2009
- Assessment of Left Ventricular Function by Intensivists Using Hand-Held EchocardiographyChest, 2009
- Focused training for goal-oriented hand-held echocardiography performed by noncardiologist residents in the intensive care unitIntensive Care Medicine, 2007
- Diagnosis of left ventricular diastolic dysfunction in the setting of acute changes in loading conditionsCritical Care, 2007
- Point of care ultrasound for basic haemodynamic assessment: novice compared with an expert operatorAnaesthesia, 2006
- DIAGNOSTIC ACCURACY OF LEFT VENTRICULAR FUNCTION FOR IDENTIFYING SEPSIS AMONG EMERGENCY DEPARTMENT PATIENTS WITH NONTRAUMATIC SYMPTOMATIC UNDIFFERENTIATED HYPOTENSIONShock, 2005
- Hemodynamic assessment of critically ill patients using echocardiography DopplerCurrent Opinion in Critical Care, 2005
- Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patientsJournal of Cardiothoracic and Vascular Anesthesia, 2005
- Focused Training of Emergency Medicine Residents in Goal-directed Echocardiography: A Prospective StudyAcademic Emergency Medicine, 2003
- Accuracy of Emergency Physician Assessment of Left Ventricular Ejection Fraction and Central Venous Pressure Using EchocardiographyAcademic Emergency Medicine, 2003