Evaluation of Common Mode Disturbance Mitigation Devices in AC Motor Drives through HF Modelling
- 1 July 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 2315-2320
Abstract
In this paper a method for verifying the performance of both passive filters and active compensation devices for common mode disturbance mitigation in PWM induction motor drive is presented. The method is based on the use of a lumped parameters HF circuit model of the whole drive simple to be implemented and studied through a standard circuit simulation software such as PSpice. Two solutions to reduce the common mode current flowing through the earth connection of the motor have been set up, these solutions are based respectively on a passive common mode choke and on an active common mode canceller. The comparison between simulated data and experimental tests allows to assess the suitability of the proposed model to accurately predict the impact of the different mitigation devices on common mode HF currents propagating within the driveKeywords
This publication has 7 references indexed in Scilit:
- Common- and Differential-Mode HF Current Components in AC Motors Supplied by Voltage Source InvertersIEEE Transactions on Power Electronics, 2004
- An accurate high frequency model of AC PWM drive systems for EMC analysis2002
- Circuit configurations and performance of the active common-noise canceler for reduction of common-mode voltage generated by voltage-source PWM inverters2000
- Induction motor high frequency model1999
- An active circuit for cancellation of common-mode voltage generated by a PWM inverterIEEE Transactions on Power Electronics, 1998
- Measurement and reduction of EMI radiated by a PWM inverter-fed AC motor drive systemIEEE Transactions on Industry Applications, 1997
- Complex-curve fittingIRE Transactions on Automatic Control, 1959