Test-Retest Reliability of the Progressive Isoinertial Lifting Evaluation (PILE)
Authors:
- Hildegunn LygrenHLHildegunn Lygren
- Tove DragesundTDTove Dragesund
- Jón JoensenJJJón Joensen
- Tove AskTATove Ask
- Rolf Moe-NilssenRMRolf Moe-Nilssen
- 1 May 2005
- journal article
- Published by Wolters Kluwer Health in Spine
- Vol. 30 (9) , 1070-1074
Abstract
A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.Keywords
This publication has 18 references indexed in Scilit:
- Short-term repeatability of body sway during quiet standing in people with hemiparesis and in frail older adultsArchives of Physical Medicine and Rehabilitation, 2004
- On the Nature of Illness and Disability: An EditorialClinical Orthopaedics and Related Research, 1997
- The Association Between Clinical Findings on Physical Examination and Self-Reported Severity in Back PainSpine, 1997
- Statistics Notes: Measurement errorBMJ, 1996
- The disability rating index: An instrument for the assessment of disability in clinical settingsJournal of Clinical Epidemiology, 1994
- Physical Progress and Residual Impairment Quantification After Functional Restoration|Part IIISpine, 1994
- Progressive Isoinertial Lifting EvaluationSpine, 1988
- 1987 Volvo Award in Clinical Sciences: A New Clinical Model for the Treatment of Low-Back PainSpine, 1987
- Quantification of Lumbar FunctionSpine, 1985
- Pain measurement and pain behaviorPain, 1984