Evaluation of the Effects of Airflow Distribution Patterns on Deposit Coverage and Spray Penetration in Multi-Unit Air-Assisted Sprayer
Open Access
Abstract
Efficient utilization is a pre-requisite for pesticide reduction, and appropriate airflow distribution pattern plays a key role in enhancing the effectiveness of pesticide application by air-assisted orchard sprayers, yet the mechanism of this is unclear. In order to clarify the specific effects of airflow velocity and direction on spraying efficacy, a series of spray tests on pear and cherry and airflow distribution tests in open areas were conducted by a multi-unit air-assisted sprayer on ten different fan settings. Several deposit indicators were analyzed and contrasted with the air distribution. The results showed that an increase in airflow velocity inside the canopy improved the abaxial side deposit coverage of both pear (from 3.33% to 11.80% in the Top canopy and from 6.26% to 11.00% in the Upper canopy) and cherry leaves (from 3.61% to 10.87% in the Top canopy, from 1.36% to 9.04% in the Middle canopy, and from 3.40% to 9.04% in the Bottom canopy), but had no significant effect on the spray penetration. The correlation between deposit indicators and airflow velocities/directions was evaluated, and the results indicated that the enhanced airflow velocities, both in the forward and horizontal direction, improved the abaxial side deposit coverage (CAB) on the outside of pear canopy (p < 0.001), but for cherry, none of the airflow indicators had a significant impact on the CAB independently. On the other hand, the increased airflow direction angle in the cross-row plane for pear, as well as the increased airflow velocities in forward and vertical direction for cherry, both showed negative effects on the adaxial side deposit coverage (p < 0.01). The findings in this study might be helpful to improve the performance of pesticide application in orchards, especially for abaxial side deposition, and could provide a reference for the further investigations about the effect of airflow on spray canopy deposition.Keywords
Funding Information
- National Natural Science Foundation of China (31761133019)
- the Modern Agricultural Industry Technology System of China (CARS-28)
- Deutsche Forschungsgemeinschaft (391697993)
This publication has 44 references indexed in Scilit:
- Analysis of the Air Flow Generated by an Air-Assisted Sprayer Equipped with Two Axial Fans Using a 3D Sonic AnemometerSensors, 2012
- Wind induced deformation and vibration of a Platanus acerifolia leafActa Mechanica Sinica, 2012
- A review of methods and applications of the geometric characterization of tree crops in agricultural activitiesComputers and Electronics in Agriculture, 2012
- Influence of nozzle type and size on drift potential by means of different wind tunnel evaluation methodsBiosystems Engineering, 2009
- Performance of some variable selection methods when multicollinearity is presentChemometrics and Intelligent Laboratory Systems, 2005
- Spray deposits and losses in different sized apple trees from an axial fan orchard sprayer: 3. Effects of air volumetric flow rateCrop Protection, 2003
- PA—Precision AgricultureJournal of Agricultural Engineering Research, 2000
- The Performance of an Air-assisted Sprayer operating in VinesJournal of Agricultural Engineering Research, 2000
- A comparison of the drift potential of a novel twin fluid nozzle with conventional low volume flat fan nozzles when using a range of adjuvantsCrop Protection, 1996
- Studies of the distribution, drift, and volatilization of diazinon resulting from spray application to a dormant peach orchardChemosphere, 1990