Abstract
The mechanical behaviors of an innovative joint, the side-plate joint, that connects a walled concrete-filled steel tubular column and an H-shaped steel beam, were analytically and experimentally investigated. The mechanical characteristics of the joint panel zone under shear were studied. A three-stage shear-yield model was established for describing the relation between shear force and shear deformation of the joint panel zone. Three failure modes and the corresponding evaluating criteria were proposed for design practices based on the shear-yield model and internal force transfer mechanism. To verify the reliability of the proposed method, three full-scale walled concrete-filled steel tubular column joints were tested under cyclic loads. Moreover, the hysteresis curve, skeleton curve, ductility, energy dissipation capacity, stiffness degradation, and strain of the joint were evaluated based on the experimental results. The predicted failure mode and ultimate bearing capacity predicted by the proposed method show good agreement with the test results; the hysteresis loop of the specimen is relatively full and shuttle-shaped without discernible pinching, which indicates the side-plate joint exhibits preferable deformation performance and possesses an energy dissipation capacity.