Overflow analysis in the fixed-point implementation of the first-order Goertzel algorithm for complex-valued input sequences
- 1 August 2009
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15483746,p. 620-623
Abstract
The first-order Goertzel algorithm has advantages over the second-order Goertzel algorithm for fixed-point implementations due in part to the small scaling factor required to avoid overflow. The first-order system can achieve better accuracy on the computed Fourier coefficients than the second-order system if same size multipliers and adders are used. And when it is implemented as a completely parallelized system, fewer resources are required. In this paper, it is demonstrated that for complex-valued input sequences the known scaling factor 1/N does not guarantee that overflows are avoided in fixed-point implementations of the first-order Goertzel algorithm. An analysis is carried out and a new scaling factor equal to 1/(4N/pi) is proposed. The use of the new scaling factor guarantees that overflow will never happen even for complex-valued input sequences.Keywords
This publication has 5 references indexed in Scilit:
- FPGA-Based Spectrum Analyzer with High Area Efficiency by Goertzel Algorithm2008
- Focus plane detection criteria in digital holography microscopy by amplitude analysisOptics Express, 2006
- T-ray Imaging and TomographyJournal of Biological Physics, 2003
- Efficient dual-tone multifrequency detection using the nonuniform discrete Fourier transformIEEE Signal Processing Letters, 1998
- Overflow analysis of a fixed-point implementation of the Goertzel algorithmIEEE Transactions on Circuits and Systems, 1989