Ultra-Low Power Estimation of Heart Rate Under Physical Activity Using a Wearable Photoplethysmographic System
- 27 October 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 553-560
Abstract
In the last years, the need for enhancing health and preventing problems with remote monitoring is increasing. A non-invasive low-cost technique for processing bio-signals and monitoring vital parameters, at rest and during physical activity, is the use of wearable PhotoPlethysmoGraphic (PPG) systems. However, in order to detect a relevant vital parameter, such as the heart rate during demanding exercises, motion artifacts must be removed from the signals retrieved. In this paper, we present a fast and easy to implement algorithm to estimate the heart rate value which does not need to reconstruct the noise-free signal nor does it apply adaptive filtering as existing algorithms, thus gaining computational time and stored memory space. The method consists of applying the Fast Fourier Transform on short windows of data and removing motion artifacts relying on single-sided amplitude spectrum analysis of PPG and 3-axis accelerometer signals. The results show that our algorithm manages to remove a wide range of motion artifacts achieving an average absolute error of only 1.27 BPM between the heart rate estimated by the algorithm every second and the ground-truth value. The method was successfully implemented on a wearable PPG device achieving an execution time of 226 ms per second, hence obtaining a battery lifetime of 9.37 days.Keywords
This publication has 8 references indexed in Scilit:
- Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum ReconstructionIEEE Transactions on Biomedical Engineering, 2015
- TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical ExerciseIEEE Transactions on Biomedical Engineering, 2014
- Wearable Photoplethysmographic Sensors—Past and PresentElectronics, 2014
- Optical heart rate monitoring module validation study2013
- Relationship Between Measurement Site and Motion Artifacts in Wearable Reflected PhotoplethysmographyJournal of Medical Systems, 2010
- Use of Fourier Series Analysis for Motion Artifact Reduction and Data Compression of Photoplethysmographic SignalsIEEE Transactions on Instrumentation and Measurement, 2008
- Arm constraint and walking in healthy adultsGait & Posture, 2007
- Effects of walking velocity on vertical head and body movements during locomotionExperimental Brain Research, 1999