Silk and PEG as means to stiffen a parylene probe for insertion in the brain: toward a double time-scale tool for local drug delivery
- 19 October 2015
- journal article
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 25 (12) , 125003
Abstract
The use of soft materials as substrate for neural probes aims at achieving better compliance with the surrounding neurons while maintaining minimal rejection. Many strategies have emerged to enable such probes to penetrate the cortex, among which the use of resorbable polymers. We performed several tests involving two resorbable polymers considered most promising: polyethylene glycol (PEG) and silk fibroin (SF) from Bombyx Mori silkworms. Our coating method provides a repeatable, uniform structure optimized for a stress-reduced insertion of a parylene-C neural probe. Standard compression tests as well as in vitro and in vivo insertion assessments show that both SF and PEG-coated probes are stiff enough to avoid the buckling effect during insertion in the cortex. However, with a buckling force of 300 mN and a mechanical holding in vitro of tens of minutes, we assess silk fibroin to be more reliable for practical handling. In vivo first try-outs in mouse brain showed neither buckling issues of the probe nor undesired alteration of the signal recording. Moreover, we evidenced two distinct time scales in the bioresorption of our polymer coatings: silk fibroin degrades itself in a matter of weeks and PEG dissolves itself within seconds in the presence of water. We then present a hybrid PEG and SF coating that could be used as a drug delivery system with different time scales to reduce both the acute and the chronic body reaction.Keywords
This publication has 52 references indexed in Scilit:
- A new MEMS neural probe integrated with embedded microfluidic channel for drug delivery and electrode array for recording neural signal2013
- Bridging the Brain to the World: A Perspective on Neural Interface SystemsNeuron, 2008
- Fabrication of Flexible Neural Probes With Built-In Microfluidic Channels by Thermal Bonding of ParyleneJournal of Microelectromechanical Systems, 2006
- Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertionJournal of Neural Engineering, 2006
- Flexible Intracortical Neural Probe with Biodegradable Polymer for Delivering Bioactive Components2006
- Learning to Control a Brain–Machine Interface for Reaching and Grasping by PrimatesPLOS Biology, 2003
- Brain responses to micro-machined silicon devicesBrain Research, 2003
- Stability of the interface between neural tissue and chronically implanted intracortical microelectrodesIEEE Transactions on Rehabilitation Engineering, 1999
- Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortexIEEE Transactions on Biomedical Engineering, 1992
- Long-term implants of Parylene-C coated microelectrodesMedical & Biological Engineering & Computing, 1988