Transcardiopulmonary vs Pulmonary Arterial Thermodilution Methods for Hemodynamic Monitoring of Burned Patients
Authors:
- 1 January 2002
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Burn Care & Rehabilitation
- Vol. 23 (1) , 21-26
Abstract
The objective of this study was to validate a new method of transcardiopulmonary thermodilution for assessment of cardiac index (CI), stroke volume index (SVI), systemic vascular resistance index (SVRI) and additional parameters such as intrathoracic blood volume index and extravascular lung water index (EVLWI) by comparison with conventional pulmonary artery catheter values in a severely burned population. The pulmonary artery measurements were performed continuously with the Vigilance system, and the transcardiopulmonary thermodilution with the PiCCO® system. One hundred thirteen measurements with each system on up to six consecutive days were taken in 14 severely burned patients (average TBSA, 49.6%; average ABSI, 10.3), aged 21 to 61 years (mean, 42.2 years) and compared intraindividually. An excellent correlation between the two methods was shown for CI (r = 0.80) and its derived parameters SVI and SVRI in states of low to normal cardiac output. The correlation was poor for cardiac indices greater then 5.5 up to their maximum values (r = 0.46). No correlation between index of oxygenation (PaO2/FiO2) vs EVLW I was observed. There was no difference between survivors and nonsurvivors, and between patients with and without inhalation injury in EVLWI. The method of transcardiopulmonary thermodilution is suitable to assess SVI, CI and SVRI under the special pathophysiologic condition of a major burn for low to normal cardiac output states. It is less reliable when cardiac output is high. The lower cost and less invasive nature are the advantages of the system compared with use of the pulmonary artery catheter. The role of intrathoracic blood volume index and EVLWI in cardiopulmonary monitoring of severely burned patients remains to be further determined.Keywords
This publication has 17 references indexed in Scilit:
- Intrathoracic Blood Volume as an End Point in Resuscitation of the Severely Burned: An Observational Study of 24 Patients2000
- Swan song for the Swan-Ganz catheter?BMJ, 1996
- The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III PatientsJAMA, 1996
- Doppelindikatormethoden als Monitoring in der IntensivmedizinAINS - Anästhesiologie · Intensivmedizin · Notfallmedizin · Schmerztherapie, 1996
- Intrathoracic blood volume accurately reflects circulatory volume status in critically ill patients with mechanical ventilationIntensive Care Medicine, 1992
- Adequate resuscitation of burn patients may not be measured by urine output and vital signsCritical Care Medicine, 1991
- Clinical Relevance of Lung Water Measurement with the Thermal-Dye Dilution Technique1990
- Development and Significance of Lung Water Measurement in Clinical and Experimental Practice1990
- Does the pulmonary capillary wedge pressure predict left ventricular preload in critically ill patients?Critical Care Medicine, 1981
- PHYSIOLOGICAL RESPONSE TO CRYSTALLOID RESUSCITATION OF SEVERE BURNSAnnals of the New York Academy of Sciences, 1968