How accurate are the wrist-based heart rate monitors during walking and running activities? Are they accurate enough?
Top Cited Papers
Open Access
- 25 April 2016
- journal article
- Published by BMJ in BMJ Open Sport & Exercise Medicine
- Vol. 2 (1) , e000106
Abstract
Background Heart rate (HR) monitors are valuable devices for fitness-orientated individuals. There has been a vast influx of optical sensing blood flow monitors claiming to provide accurate HR during physical activities. These monitors are worn on the arm and wrist to detect HR with photoplethysmography (PPG) techniques. Little is known about the validity of these wearable activity trackers. Aim Validate the Scosche Rhythm (SR), Mio Alpha (MA), Fitbit Charge HR (FH), Basis Peak (BP), Microsoft Band (MB), and TomTom Runner Cardio (TT) wireless HR monitors. Methods 50 volunteers (males: n=32, age 19–43 years; females: n=18, age 19–38 years) participated. All monitors were worn simultaneously in a randomised configuration. The Polar RS400 HR chest strap was the criterion measure. A treadmill protocol of one 30 min bout of continuous walking and running at 3.2, 4.8, 6.4, 8.0, and 9.6 km/h (5 min at each protocol speed) with HR manually recorded every minute was completed. Results For group comparisons, the mean absolute percentage error values were: 3.3%, 3.6%, 4.0%, 4.6%, 4.8% and 6.2% for TT, BP, RH, MA, MB and FH, respectively. Pearson product-moment correlation coefficient (r) was observed: r=0.959 (TT), r=0.956 (MB), r=0.954 (BP), r=0.933 (FH), r=0.930 (RH) and r=0.929 (MA). Results from 95% equivalency testing showed monitors were found to be equivalent to those of the criterion HR (±10% equivalence zone: 98.15–119.96). Conclusions The results demonstrate that the wearable activity trackers provide an accurate measurement of HR during walking and running activities.Keywords
This publication has 12 references indexed in Scilit:
- Comparison of Polar®RS800G3™ heart rate monitor with Polar® S810i™ and electrocardiogram to obtain the series of RR intervals and analysis of heart rate variability at restClinical Physiology and Functional Imaging, 2014
- Validity of Consumer-Based Physical Activity MonitorsMedicine & Science in Sports & Exercise, 2014
- Comparison of heart rate measured by Polar RS400 and ECG, validity and repeatabilityAdvances in Physiotherapy, 2012
- Validity of the Smarthealth Watch to Measure Heart Rate During Rest and ExerciseMeasurement in Physical Education and Exercise Science, 2011
- Validation of Heart Rate Monitor-Based Predictions of Oxygen Uptake and Energy ExpenditureJournal of Strength & Conditioning Research, 2009
- Global positioning system: a new opportunity in physical activity measurementInternational Journal of Behavioral Nutrition and Physical Activity, 2009
- Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-livingEuropean Journal of Applied Physiology, 2005
- Validity of Seven Commercially Available Heart Rate MonitorsMeasurement in Physical Education and Exercise Science, 2002
- Heart rate monitors: State of the artJournal of Sports Sciences, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986