Abstract
Iterative image reconstruction algorithms have the potential to produce low noise images. Early stopping of the iteration process is problematic because some features of the image may converge slowly. On the other hand, there may be noise build-up with increased number of iterations. Therefore, we examined the stabilizing effect of using two different prior functions as well as image representation by blobs so that the number of iterations could be increased without noise build-up. Reconstruction was performed of simulated phantoms and of real data acquired by positron emission tomography. Image quality measures were calculated for images reconstructed with or without priors. Both priors stabilized the iteration process. The first prior based on the Huber function reduced the noise without significant loss of contrast recovery of small spots, but the drawback of the method was the difficulty in finding optimal values of two free parameters. The second method based on a median root prior has only one Bayesian parameter which was easy to set, but it should be taken into account that the image resolution while using that prior has to be chosen sufficiently high not to cause the complete removal of small spots. In conclusion, the Huber penalty function gives accurate and low noise images, but it may be difficult to determine the parameters. The median root prior method is not quite as accurate but may be used if image resolution is increased.Keywords
This publication has 20 references indexed in Scilit:
- Tomographic Image Reconstruction Based on a Content-Adaptive Mesh ModelIEEE Transactions on Medical Imaging, 2004
- Generalization of median root prior reconstructionIEEE Transactions on Medical Imaging, 2002
- Bayesian image reconstruction for emission tomography based on median root priorEuropean Journal of Nuclear Medicine and Molecular Imaging, 1997
- Multidimensional Optimization in Image Reconstruction from Projections1997
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Bayesian reconstructions from emission tomography data using a modified EM algorithmIEEE Transactions on Medical Imaging, 1990
- A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priorsIEEE Transactions on Medical Imaging, 1989
- Local basis-function approach to computed tomographyApplied Optics, 1985
- Finite series-expansion reconstruction methodsProceedings of the IEEE, 1983
- Iterative reconstruction algorithmsComputers in Biology and Medicine, 1976