Biological Reactions to Metal Particles and Ions in the Synovial Layer of Mice
Open Access
Abstract
Metal particles and ions released from implants not only have a fundamental effect on the longevity of total joint replacements, but can also be disseminated to remote organs. Periprosthetic tissues harvested during revision surgeries mainly reflect end-stage failure but may not adequately reveal initial biological reactions and systemic side effects. Therefore, primary reactions caused by metal particles and ions were investigated in an established murine model. Left knee joints in three groups, each consisting of ten female BALB/c mice, received injections of metal ions (MI), metal particles (MP) and phosphate-buffered saline (PBS) (control). Seven days after the injection, immunohistochemical analyses of the synovial layer were performed with respect to some biological markers including Tumor necrosis factor -α (TNF-α), Interleukin-6 (IL-6), Interleukin-1β (IL-1β), Cluster of Differentiation 45 (CD45), Cluster of Differentiation 68 (CD68) and Cluster of Differentiation 3(CD3). The MP group showed significantly enhanced proinflammatory cytokine expression (TNF-α, IL-6 and IL-1β) compared with the other groups (p < 0.05). Interestingly, CD3, as a marker for T lymphocytes, did not increase in any of the groups. The MI group showed a significantly increased expression of CD45 compared with the control group (p < 0.05). Therefore, during the primary process, metal particles have stronger pro-inflammatory potential than metal ions, and T lymphocytes did not seem to be activated in our murine model. Systemic reactions caused by metal particles and ions were found by observing the untreated right knees.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (UT 119/3-1)
- China Scholarship Council (201708140085)
This publication has 57 references indexed in Scilit:
- Electrochemical control of cell death by reduction-induced intrinsic apoptosis and oxidation-induced necrosis on CoCrMo alloy in vitroBiomaterials, 2012
- Pseudotumor in a Well-Fixed Metal-on-Polyethylene Uncemented Hip ArthroplastyThe Journal of Arthroplasty, 2012
- An introduction to immunology and immunopathologyAllergy, Asthma & Clinical Immunology, 2011
- Characterization of wear particles generated from CoCrMo alloy under sliding wear conditionsWear, 2011
- Histological Features of Pseudotumor-like Tissues From Metal-on-Metal HipsClinical Orthopaedics and Related Research, 2010
- Soluble and particulate Co‐Cr‐Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: A novel mechanism for implant debris reactivityJournal of Orthopaedic Research, 2008
- Necrotic granulomatous pseudotumours in bilateral resurfacing hip arthoplasties: evidence for a type IV immune responseVirchows Archiv, 2008
- An in vivo murine model of continuous intramedullary infusion of polyethylene particlesBiomaterials, 2008
- Wear particles, periprosthetic osteolysis and the immune systemBiomaterials, 2007
- Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapiesArthritis Research & Therapy, 2007