Aortic Valve Area and Strain Measurements by Cardiac MRI and Transthoracic Echocardiography in Severe Aortic Stenosis with Normal Left Ventricular Function
Authors:
Open Access
- journal article
- research article
- Vol. 48 (4) , 370-378
Abstract
Background: Transthoracic echocardiography (TTE) is the recommended imaging technique for the evaluation of patients with aortic stenosis (AS). However, in cases with inconclusive findings, cardiac magnetic resonance (CMR) planimetry is used to grade AS severity. This study aimed to compare the results derived from TTE and CMR in patients with severe AS with normal left ventricular (LV) function. Methods: In a prospective study, 20 patients with severe AS were recruited and data derived from TTE and CMR modalities were compared with the archived records of 28 age- and sex-matched healthy controls. The data included aortic valve area (AVA), MRI-derived biventricular global strains, and TTEderived global longitudinal strain (GLS). SPSS software was used to analyze the data with independent samples t test, intraclass correlation coefficient ( ICC), and Pearson correlation. P<0.05 was considered statistically significant. Results: An excellent agreement was found in AVA values derived from CMR and TTE with an average ICC of 0.932 (95% CI=0.829-0.973). There was a significant difference in LV- GLS, LV global radial strain (GRS), right ventricular (RV) GRS, and RV global circumferential strain between the groups. A good correlation was found between CMR- and TTE-derived GLS with an average ICC of 0.721 (95% C= 0.255-0.896). The mean aortic valve pressure gradient in TTE had a significant inverse linear correlation with LV-GRS in CMR (r=-0.537). All P values were <0.05. Conclusion: There was a good agreement between AVA and strain values derived from cardiac MRI and TTE. The myocardial strain was impaired in patients with severe AS and normal LV function and correlated with disease severity.Keywords
This publication has 32 references indexed in Scilit:
- Global Strain in Severe Aortic Valve StenosisCirculation: Cardiovascular Imaging, 2012
- Global Longitudinal Strain in Relation to the Severity of Aortic Stenosis: A Two-Dimensional Speckle-Tracking StudyEchocardiography, 2011
- Alterations in multidirectional myocardial functions in patients with aortic stenosis and preserved ejection fraction: a two-dimensional speckle tracking analysisEuropean Heart Journal, 2011
- Current and Evolving Echocardiographic Techniques for the Quantitative Evaluation of Cardiac Mechanics: ASE/EAE Consensus Statement on Methodology and IndicationsJournal of the American Society of Echocardiography, 2011
- Survival Benefit of Aortic Valve Replacement in Patients With Severe Aortic Stenosis With Low Ejection Fraction And Low Gradient With Normal Ejection FractionThe Annals of Thoracic Surgery, 2008
- Assessment of Aortic Valve Area in Aortic Stenosis Using Cardiac Magnetic Resonance Tomography: Comparison with EchocardiographyCardiology, 2007
- Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of CardiologyEuropean Heart Journal, 2006
- Evaluation of aortic stenosis by cardiovascular magnetic resonance imaging: comparison with established routine clinical techniquesHeart, 2004
- Valve area and cardiac output in aortic stenosis: Quantification by magnetic resonance velocity mappingAmerican Heart Journal, 1993
- Prevalence of aortic valve abnormalities in the elderly: An echocardiographic study of a random population sampleJACC, 1993