Analysis of power loss in Ni–Zn ferrites

Authors:

Abstract
The power loss (Pcv) was analyzed by combining two methods. The first, Pcv, is divided into hysteresis loss (Ph) and residual loss (Pr) from the frequency dependence of the power loss according to the method of Otsuki et al., and, second, the loss factors are attributed to domain wall motion (Pw) and the rotation magnetization (Prot) by adapting the method proposed by Visser et al. It was found that Pw coincides with Ph in the lower frequency range, but the difference between them becomes significant as frequency goes up. The higher value of Pw, in comparison with Ph in the higher frequency range, can be attributed to the enhancement of loss due to the dynamic motion of the domain wall (Pwd) by raising the frequency. The hysteresis loss dominates Pcv in the frequency range below 500 kHz, while Pwd becomes predominant factor in the higher frequency range more than 500 kHz.