Analysis of power loss in Ni–Zn ferrites
Authors:
- 28 April 2000
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 87 (9) , 6229-6231
Abstract
The power loss was analyzed by combining two methods. The first, is divided into hysteresis loss and residual loss from the frequency dependence of the power loss according to the method of Otsuki et al., and, second, the loss factors are attributed to domain wall motion and the rotation magnetization by adapting the method proposed by Visser et al. It was found that coincides with in the lower frequency range, but the difference between them becomes significant as frequency goes up. The higher value of in comparison with in the higher frequency range, can be attributed to the enhancement of loss due to the dynamic motion of the domain wall by raising the frequency. The hysteresis loss dominates in the frequency range below 500 kHz, while becomes predominant factor in the higher frequency range more than 500 kHz.
Keywords
This publication has 2 references indexed in Scilit:
- Analysis of the complex permeability of monocrystalline MnZnFeII ferriteJournal of Magnetism and Magnetic Materials, 1984
- Determination of the domain wall energy from hysteresis loops in YIGPhysica Status Solidi (b), 1973