Biomechanical Changes of the Lumbar Segment after Total Disc Replacement : Charite®, Prodisc® and Maverick® Using Finite Element Model Study
Open Access
- 1 January 2010
- journal article
- Published by Korean Neurosurgical Society in Journal of Korean Neurosurgical Society
- Vol. 47 (6) , 446-53
Abstract
The purpose of this study was to analyze the biomechanical effects of three different constrained types of an artificial disc on the implanted and adjacent segments in the lumbar spine using a finite element model (FEM). The created intact model was validated by comparing the flexion-extension response without pre-load with the corresponding results obtained from the published experimental studies. The validated intact lumbar model was tested after implantation of three artificial discs at L4-5. Each implanted model was subjected to a combination of 400 N follower load and 5 Nm of flexion/extension moments. ABAQUS version 6.5 (ABAQUS Inc., Providence, RI, USA) and FEMAP version 8.20 (Electronic Data Systems Corp., Plano, TX, USA) were used for meshing and analysis of geometry of the intact and implanted models. Under the flexion load, the intersegmental rotation angles of all the implanted models were similar to that of the intact model, but under the extension load, the values were greater than that of the intact model. The facet contact loads of three implanted models were greater than the loads observed with the intact model. Under the flexion load, three types of the implanted model at the L4-5 level showed the intersegmental rotation angle similar to the one measured with the intact model. Under the extension load, all of the artificial disc implanted models demonstrated an increased extension rotational angle at the operated level (L4-5), resulting in an increase under the facet contact load when compared with the adjacent segments. The increased facet load may lead to facet degeneration.Keywords
This publication has 25 references indexed in Scilit:
- Biomechanical Effect of Constraint in Lumbar Total Disc ReplacementSpine, 2009
- Total disc replacement in the lumbar spine: a systematic review of the literatureEuropean Spine Journal, 2006
- A Prospective, Randomized, Multicenter Food and Drug Administration Investigational Device Exemption Study of Lumbar Total Disc Replacement With the CHARITÉ ™ Artificial Disc Versus Lumbar FusionSpine, 2005
- Biomechanical studies of an artificial disc implant in the human cadaveric spineJournal of Neurosurgery: Spine, 2005
- Revision of a Charité artificial disc 9.5 years in vivo to a new Charité artificial disc: case report and explant analysisEuropean Spine Journal, 2005
- Statistical factorial analysis on the material property sensitivity of the mechanical responses of the C4–C6 under compression, anterior and posterior shearJournal of Biomechanics, 2004
- Effects of lumbar spinal fusion on the other lumbar intervertebral levels (three-dimensional finite element analysis)Journal of Orthopaedic Science, 2003
- Analysis of Compression Behavior in Lumbar Spine - Under Simple Vertical Load vs Follower Load -Journal of Korean Society of Spine Surgery, 2002
- Rate effect on sharing of passive lumbar motion segment under load-controlled sagittal flexion: viscoelastic finite element analysisTheoretical and Applied Fracture Mechanics, 1999
- Three-Dimensional Movements of the Whole Lumbar Spine and Lumbosacral JointSpine, 1989