Monitoring relative fluid balance alterations in haemodialysis of diabetic patients by electrical impedance
Authors:
- 1 February 1998
- journal article
- clinical trial
- Published by IOP Publishing in Physiological Measurement
- Vol. 19 (1) , 35-52
Abstract
Measurements of total-body electrical impedance in the frequency range between 200 Hz and 300 kHz were performed on 37 diabetic patients undergoing chronic haemodialysis. Special attention was paid to the instrument design, where a self-balancing differential current source was used, reducing considerably the common-mode voltage at the amplifier input. The patient-instrument interface includes screened leads, separately driven by unity-gain buffers. The measurement error was < 1% for the impedance within the range of 20 to 1000 omega and < 0.3 degree (mean) for the phase angle. Impedance/phase and ultrafiltration measurements were carried out throughout the entire procedure. Total and extracellular water were computed and compared with extracted fluid volumes. The trends of change of the extracellular and intracellular fluid volumes during and immediately after dialysis corresponded to the respective clinical condition of the patients and enabled us to divide them into four groups. This approach is a step toward continuous monitoring and adaptive treatment, tailored to the individual patient needs.Keywords
This publication has 32 references indexed in Scilit:
- Water distribution in insulin-dependent diabetes mellitus in various states of metabolic controlEuropean Journal of Endocrinology, 1996
- Mechanical and physiologic modifiers and bioelectrical impedance spectrum determinants of body compositionThe American Journal of Clinical Nutrition, 1996
- Multi-frequency bioelectrical impedance: a comparison between the Cole-Cole modelling and Hanai equations with the classical impedance index approachAnnals of Human Biology, 1996
- Comparison of Bio-Impedance Spectroscopy and Multi-Frequency Bio-Impedance Analysis for the Assessment of Extracellular and Total Body Water in Surgical PatientsClinical Science, 1995
- Determination of Intracellular Water by Multifrequency Bioelectrical ImpedanceAnnals of Nutrition and Metabolism, 1995
- Waveform generator for electrical impedance tomography (EIT) using linear interpolation with multiplying D/A convertersJournal of Medical Engineering & Technology, 1994
- Electrical Impedance Spectroscopic Monitoring of Body Compartmental Volume ChangesJournal of Clinical Engineering, 1993
- Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHzAnnals of Biomedical Engineering, 1993
- Measurement of transcellular fluid shift during haemodialysisMedical & Biological Engineering & Computing, 1989
- The prediction of total body water using bioelectrical impedance in children and adolescentsAnnals of Human Biology, 1988