A Force Reproduction Analysis of Two Recording Sensors of a Computerized Occlusal Analysis System
- 1 January 2006
- journal article
- research article
- Published by Maney Publishing in Cranio®
- Vol. 24 (1) , 15-24
Abstract
The purpose of this study was to measure the performance of a new design of occlusal sensor, the high definition (HD) sensor, and directly compare this sensor to the previous design. This new HD sensor design has increased active recording area by 33%, and decreased inactive recording area by 50% as compared to the previous design (G3). This was accomplished by determining the force reproduction variability for repeated occlusal closures on the same sensor for a sampling of sensors from both designs. Thirty (30) G3 and 30 HD sensors were consistently positioned and loaded 24 times between articulated epoxy casts by a Pneumatic Occlusal Force Simulator. Their force reproduction consistency was measured as an electronic voltage drop across six occlusal contacts that were consistently located on all sensors. The force variability of the two sensor designs was determined by comparing the consistency of the voltage drops across the six occlusal contacts. An analysis of variance was employed to determin...Keywords
This publication has 14 references indexed in Scilit:
- In vivo and in vitro evaluation of occlusal indicator sensitivityThe Journal of Prosthetic Dentistry, 2002
- Reliability of F-Scan In-Shoe Measurements of Plantar PressureFoot & Ankle International, 1998
- Evaluation of occlusal contacts in maximum intercuspation using the T-Scan systemJournal of Oral Rehabilitation, 1997
- Calibration and Use of Grid-Based Tactile Pressure Sensors in Granular MaterialGeotechnical Testing Journal, 1997
- Analysis of two methods for occlusal contact registration with the T-Scan systemJournal of Oral Rehabilitation, 1997
- Calcaneocuboid Joint Pressures with Lateral Column Lengthening (Evans) ProcedureFoot & Ankle International, 1997
- Study of occlusal contact variability within individuals in a position of maximum intercuspation usingthe T-SCAN systemJournal of Oral Rehabilitation, 1997
- Electromyographic and computer analyses of patients suffering from chronic myofascial pain-dysfunction syndrome: Before and after treatment with immediate complete anterior guidance developmentThe Journal of Prosthetic Dentistry, 1991
- Computerized occlusal analysis: An evaluation of the sensorsThe Journal of Prosthetic Dentistry, 1991
- Distribution of occlusal contacts in maximum intercuspationThe Journal of Prosthetic Dentistry, 1989