Virtual simulation with Sim&Size software for Pipeline Flex Embolization: evaluation of the technical and clinical impact
- 28 February 2020
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 12 (10) , 968-973
Abstract
Introduction During flow diversion, the choice of the length, diameter, and location of the deployed stent are critical for the success of the procedure. Sim&Size software, based on the three-dimensional rotational angiography (3D-RA) acquisition, simulates the release of the stent, suggesting optimal sizing, and displaying the degree of the wall apposition. Objective To demonstrate technical and clinical impacts of the Sim&Size simulation during treatment with the Pipeline Flex Embolization Device. Methods Consecutive patients who underwent aneurysm embolization with Pipeline at our department were retrospectively enrolled (January 2015–December 2017) and divided into two groups: treated with and without simulation. Through univariate and multivariate models, we evaluated: (1) rate of corrective intervention for non-optimal stent placement, (2) duration of intervention, (3) radiation dose, and (4) stent length. Results 189 patients, 95 (50.2%) without and 94 (49.7%) with software assistance were analyzed. Age, sex, comorbidities, aneurysm characteristics, and operator’s experience were comparable among the two groups. Procedures performed with the software had a lower rate of corrective intervention (9% vs 20%, p=0.036), a shorter intervention duration (46 min vs 52 min, p=0.002), a lower median radiation dose (1150 mGy vs 1558 mGy, pConclusions In our experience, the use of the virtual simulation during Pipeline treatment significantly reduced the need for corrective intervention, the procedural time, the radiation dose, and the length of the stent.Keywords
This publication has 18 references indexed in Scilit:
- Variable Porosity of the Pipeline Embolization Device in Straight and Curved Vessels: A Guide for Optimal Deployment StrategyAmerican Journal of Neuroradiology, 2013
- Silent embolism after stent-assisted coiling of cerebral aneurysms: diffusion-weighted MRI study of 75 casesJournal of NeuroInterventional Surgery, 2013
- Endovascular Treatment of Intracranial Aneurysms With Flow DivertersStroke, 2013
- Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysmsJournal of Biomechanics, 2012
- Safety of the Pipeline Embolization Device in Treatment of Posterior Circulation AneurysmsAmerican Journal of Neuroradiology, 2012
- Pipeline embolization device (PED) for neurovascular reconstruction: initial experience in the treatment of 101 intracranial aneurysms and dissectionsNeuroradiology, 2011
- Effective Doses in Radiology and Diagnostic Nuclear Medicine: A CatalogRadiology, 2008
- Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiologyBritish Journal of Radiology, 2004
- Clinical events following neuroangiography: a prospective study.Stroke, 1987
- Complications of catheter cerebral arteriography: analysis of 5,000 procedures. III. Assessment of arteries injected, contrast medium used, duration of procedure, and age of patientAmerican Journal of Roentgenology, 1978