Dead Space Fraction Changes During PEEP Titration Following Lung Recruitment in Patients With ARDS
Authors:
- 1 October 2012
- journal article
- Published by SAGE Publications in Respiratory Care
- Vol. 57 (10) , 1578-1585
Abstract
Elevated dead space fraction (the ratio of dead space to tidal volume [V(D)/V(T)]) is a feature of ARDS. PEEP can partially reverse atelectasis, prevent alveoli recollapse, and improve lung compliance and gas exchange in patients with ARDS. However, whether V(D)/V(T) variables have a close relationship with PEEP and collapse alveolar recruitment remains under recognized. Meanwhile, few clinicians titrate PEEP in consideration of changes in V(D)/V(T). Therefore, we performed the study to evaluate V(D)/V(T), arterial oxygenation, and compliance changes during PEEP titration following lung recruitment in ARDS patients. Twenty-three ARDS patients ventilated in volume-controlled mode were enrolled in the study. Sustained inflation (40 cm H₂O, 30 s) was used as a recruitment maneuver, followed by decremental PEEP changes from 20 to 6 cm H₂O, in steps of 2 cm H₂O, and then to 0 cm H₂O. V(D)/V(T), pulmonary mechanics parameters, gas exchange parameters, and hemodynamic parameters were recorded after 20 min at each PEEP step. Compared with V(D)/V(T) at the PEEP levels of 20 cm H₂O and 0 cm H₂O, V(D)/V(T) was significantly lower at 12 cm H₂O (P = .02), and compliance of the static respiratory system (C(RS)) was significantly higher at pressure step 12/10 cm H₂O (P < .001). Compared with P(aCO₂) at the PEEP level of 20 cm H₂O, P(aCO₂) was significantly lower at 12 cm H₂O (P < .001). Arterial oxygenation values and functional residual capacity were reduced gradually during PEEP, decreasing from 20 cm H₂O to 0 cm H₂O. A significant change of V(D)/V(T), compliance and arterial oxygenation could be induced by PEEP titration in subjects with ARDS. Optimal PEEP in these subjects was 12 cm H₂O, because at this pressure level the highest compliance in conjunction with the lowest V(D)/V(T) indicated a maximum amount of effectively expanded alveoli. Monitoring of V(D)/V(T) was useful for detecting lung collapse and for establishing open-lung PEEP after a recruitment maneuver.Keywords
This publication has 28 references indexed in Scilit:
- How Much PEEP in Acute Lung InjuryJAMA, 2010
- Monitoring dead space during recruitment and PEEP titration in an experimental modelIntensive Care Medicine, 2006
- Incidence and Outcomes of Acute Lung InjuryNew England Journal of Medicine, 2005
- Effects of positive end-expiratory pressure on dead space and its partitions in acute lung injuryIntensive Care Medicine, 2002
- Pulmonary Dead-Space Fraction as a Risk Factor for Death in the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2002
- The Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- How does positive end-expiratory pressure decrease pulmonary CO2 elimination in anesthetized patients?Respiration Physiology, 1999
- Volumetric capnography in patients with acute lung injury: effects of positive end-expiratory pressureEuropean Respiratory Journal, 1999
- Different ventilatory approaches to keep the lung openIntensive Care Medicine, 1995
- Optimum End-Expiratory Airway Pressure in Patients with Acute Pulmonary FailureNew England Journal of Medicine, 1975