Discharge coefficient equation of a segmental wedge flowmeter
Authors:
- 1 February 2008
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 222 (1) , 79-83
Abstract
The discharge coefficient is reported for a flowmeter based on a segmental wedge device having a vertex angle of 90° for varying ratios of pipe diameter D to characteristic free flow dimension H at the wedge. The current work suggests that the segmental wedge makes a reliable flow-metering device, with a near constant discharge coefficient over a wide range of Reynolds numbers. A correlation is provided for the discharge coefficient as a function of H/ D.Keywords
This publication has 5 references indexed in Scilit:
- Design of a bluff body for development of variable area orifice-meterFlow Measurement and Instrumentation, 2004
- Design and development of variable area orifice meterFlow Measurement and Instrumentation, 2002
- Response of a slotted orifice flow meter to an air/water mixtureFlow Measurement and Instrumentation, 2001
- Wedge flowmeter.TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B, 1987
- A linear orifice-plate flowmeterJournal of Physics E: Scientific Instruments, 1976