Self-Healing Capability of Fiber-Reinforced Cementitious Composites for Recovery of Watertightness and Mechanical Properties
Open Access
- 13 March 2014
- Vol. 7 (3) , 2141-2154
Abstract
Various types of fiber reinforced cementitious composites (FRCCs) were experimentally studied to evaluate their self-healing capabilities regarding their watertightness and mechanical properties. Cracks were induced in the FRCC specimens during a tensile loading test, and the specimens were then immersed in static water for self-healing. By water permeability and reloading tests, it was determined that the FRCCs containing synthetic fiber and cracks of width within a certain range (<0.1 mm) exhibited good self-healing capabilities regarding their watertightness. Particularly, the high polarity of the synthetic fiber (polyvinyl alcohol (PVA)) series and hybrid fiber reinforcing (polyethylene (PE) and steel code (SC)) series showed high recovery ratio. Moreover, these series also showed high potential of self-healing of mechanical properties. It was confirmed that recovery of mechanical property could be obtained only in case when crack width was sufficiently narrow, both the visible surface cracks and the very fine cracks around the bridging of the SC fibers. Recovery of the bond strength by filling of the very fine cracks around the bridging fibers enhanced the recovery of the mechanical property.Keywords
This publication has 13 references indexed in Scilit:
- Self-Healing in Cementitious Materials—A ReviewMaterials, 2013
- Experimental Study on Self-Healing Capability of FRCC Using Different Types of Synthetic FibersJournal of Advanced Concrete Technology, 2012
- Development of Engineered Self-Healing and Self-Repairing Concrete-State-of-the-Art ReportJournal of Advanced Concrete Technology, 2012
- Quantification of crack-healing in novel bacteria-based self-healing concreteCement and Concrete Composites, 2011
- Self-healing efficiency of cementitious materials containing tubular capsules filled with healing agentCement and Concrete Composites, 2011
- Self-Healing Capability of Fibre Reinforced Cementitious CompositesJournal of Advanced Concrete Technology, 2009
- Autogenous healing of engineered cementitious composites under wet–dry cyclesCement and Concrete Research, 2009
- The Effect of Vertical Distribution of Water Permeability on the Modeled Neutralization Process in Concrete WallsJournal of ASTM International, 2007
- Development of Self-Healing System for Concrete with Selective Heating around CrackJournal of Advanced Concrete Technology, 2006
- Three designs for the internal release of sealants, adhesives, and waterproofing chemicals into concrete to reduce permeabilityCement and Concrete Research, 2000