Characterization of endotoxin and 3-hydroxy fatty acid levels in air and settled dust from commercial aircraft cabins
- 19 May 2003
- journal article
- Published by Hindawi Limited in Indoor Air
- Vol. 13 (2) , 166-173
Abstract
Endotoxin was measured in air and dust samples collected during four commercial aircraft flights. Samples were analyzed for endotoxin biological activity using the Limulus assay. 3-hydroxy fatty acids (3-OH FA) of carbon chain lengths C10:0-C18:0 were determined in dust by gas chromatography-ion trap tandem mass spectrometry. The geometric mean (geometric standard deviation) endotoxin air level was 1.5 EU/m3 (1.9, n = 28); however, significant differences were found by flight within aircraft type. Mean endotoxin levels were significantly higher in carpet dust than in seat dust (140 +/- 81 vs. 51 +/- 25 EU/mg dust, n = 32 each, P < 0.001). Airborne endotoxin levels were not significantly related to either carpet or seat dust endotoxin levels. Mean 3-OH FA levels were significantly higher in carpet dust than in seat dust for C10:2, C12:0, and C14:0 (P < 0.001 for each), while the mean level of C16:0 was significantly higher in seat dust than in carpet dust (P < 0.01). Carpet dust endotoxin was significantly, but moderately, correlated with 3-OH-C12:0 and 3-OH-C14:0 (Pearson r = 0.52 and 0.48, respectively), while correlation of seat dust endotoxin with individual 3-OH FAs depended on the test statistic used. Mean endotoxin potency was significantly higher for carpet dust than for seat dust (6.3 +/- 3.0 vs. 3.0 +/- 1.4 EU/pmol LPS, P < 0.0001). Mean endotoxin levels in the air and dust of commercial aircraft cabins were generally higher than mean levels reported in homes and office buildings. These results suggest that exposure route and dust source are important considerations when relating endotoxin exposure to specific health outcomes.Keywords
This publication has 22 references indexed in Scilit:
- Predictors of High Endotoxin Concentrations in the Settled Dust of German HomesIndoor Air, 2002
- Investigation of the Concentration of Bacteria and Their Cell Envelope Components in Indoor Air in Two Elementary SchoolsJournal of the Air & Waste Management Association, 2000
- Relation between house-dust endotoxin exposure, type 1 T-cell development, and allergen sensitisation in infants at high risk of asthmaThe Lancet, 2000
- Characterization and Variability of Endotoxin and 3-Hydroxy Fatty Acids in an Office Building During a Particle Intervention StudyIndoor Air, 2000
- Preliminary Report on the Results of the Second Phase of a Round-Robin Endotoxin Assay Study Using Cotton DustApplied Occupational and Environmental Hygiene, 2000
- Environmental Endotoxin Measurement: Interference and Sources of Variation in the Limulus Assay of House DustAIHA Journal, 1997
- Severity of Asthma Is Related to Endotoxin in House DustAmerican Journal of Respiratory and Critical Care Medicine, 1996
- Dust and the Sick Building SyndromeIndoor Air, 1994
- Environmental endotoxin measurement: The Kinetic Limulus Assay with Resistant-parallel-line EstimationEnvironmental Research, 1992
- Domestic endotoxin exposure and clinical severity of asthmaClinical & Experimental Allergy, 1991