Abstract
A microwave photonic structure for measuring the frequency of an RF signal received by an antenna is presented. The main component is an unbalanced Michelson interferometer (UMI) composed of an optical circulator, a $3\times 3$ coupler, two Faraday rotator mirrors (FRMs), and three low-speed photodetectors (PDs). The frequency of the incoming RF signal can be determined by measuring the voltages generated by the three PDs. The system does not require any RF component and can be incorporated in a conventional fiber-optic link where the antenna for receiving the RF signal is connected to a standard Mach–Zehnder modulator (MZM), for RF signal frequency measurement. High-resolution and highly accurate frequency measurement over a wide frequency range can be realized by using two UMIs with long and short path length differences. Experimental results demonstrate that the frequency of an RF signal can be determined in a 5–26 GHz measurement range, for different input RF signal power levels. Frequency measurement with a resolution of 10MHz and an accuracy better than ±10MHz is also demonstrated.
Funding Information
  • Natural Science Foundation of Hebei Province Chunhui Talent Project (F2023201072)
  • Interdisciplinary Research Program of Natural Science of Hebei University (DXK202204)

This publication has 28 references indexed in Scilit: