Comparative reproducibility of the noninvasive ultrasound methods for the assessment of vascular function
Authors:
- 13 January 2012
- journal article
- research article
- Published by Springer Nature in Heart and Vessels
- Vol. 28 (2) , 143-150
Abstract
The aim of this work was to assess the reproducibility of ultrasound parameters of vascular function, since these measurements are currently recommended by the guidelines for the evaluation of the cardiovascular risk. Twenty subjects (51 ± 17 years, 11 men) had vascular ultrasound (Aloka Prosound α10) performed by two observers, at the level of the right common carotid artery for assessment of intima-media thickness (IMT), “wall tracking”, and “wave-intensity analysis”, and at the level of the right brachial artery for the assessment of flow-mediated dilation (FMD). Wave intensity is a hemodynamic index, evaluating ventriculo-arterial interaction and can be measured in real time by a double-beam ultrasound technique through simultaneous recording of carotid arterial blood flow velocity and diameter. Carotido-femoral pulse wave velocity (PWV) was determined using the Complior method. Intra- and inter-observer reproducibility was assessed during a first session, when three consecutive acquisitions were made (first observer → second observer → first observer); repeatability was evaluated 1 week later (second observer). The most reproducible and repeatable parameters were PWV (intraobserver ±3.3%, interobserver ±2.6%, repeatability ±5.6%) and IMT (±3.7, ±4.3, ±4.9%, respectively). Intraobserver reproducibility for arterial stiffness and ventriculo-arterial coupling parameters was the highest for the beta index (±3.8%), and the lowest for the second systolic peak (±22.4%). Interobserver reproducibility and repeatability varied between very good for the wave speed (±5.5 and ±4.3%), and unsatisfactory for the negative area (±31.8 and ±38.6%). FMD had good reproducibility (intraobserver ±11.6%, interobserver ±8%, repeatability ±7%), whereas augmentation index had only satisfactory results (±17.8, ±8.4, ±23.8%, respectively). Only some parameters of vascular function have good reproducibility and repeatability, better or similar to other ultrasound methods and, therefore, these are ready to be used in routine clinical practice.Keywords
This publication has 31 references indexed in Scilit:
- “Supranormal” Cardiac Function in Athletes Related to Better Arterial and Endothelial FunctionEchocardiography, 2010
- Comparison of aortic pulse wave velocity measured by three techniques: Complior, SphygmoCor and ArteriographJournal Of Hypertension, 2008
- Mannheim Carotid Intima-Media Thickness Consensus (2004–2006)Cerebrovascular Diseases, 2006
- Intrasubject Variability of Radial Artery Flow-Mediated Dilatation in Healthy Subjects and Implications for Use in Prospective Clinical TrialsThe American Journal of Cardiology, 2005
- Effects of nitric oxide synthase inhibitor on decrease in peripheral arterial stiffness with acute low-intensity aerobic exerciseAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood PressureHypertension, 2003
- Venous duplex scanning of the leg: range, variability and reproducibilityClinical Science, 1999
- Reproducibility of In Vivo Carotid Intima-Media Thickness MeasurementsStroke, 1997
- Noninvasive quantification of atherosclerotic lesions. Reproducibility of ultrasonographic measurement of arterial wall thickness and plaque size.Arteriosclerosis and Thrombosis: A Journal of Vascular Biology, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986