Unnecessary interruptions of cardiac massage during simulated cardiac arrests
Authors:
- S. C. U. MarschSMS. C. U. Marsch
- F. TschanFTF. Tschan
- N. SemmerNSN. Semmer
- M. SpychigerMSM. Spychiger
- M. BreuerMBM. Breuer
- P. R. HunzikerPHP. R. Hunziker
- 1 November 2005
- journal article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 22 (11) , 831-833
Abstract
Background and objective: Cardiopulmonary resuscitation should not be interrupted until the return of spontaneous circulation or the decision to withhold further treatment. There are no data on how consistent in-hospital cardiopulmonary resuscitation is performed. Accordingly, the aim of the present study was to identify length and type of unnecessary interruptions in simulated cardiac arrests. Methods: The study was carried out in a patient simulator. A scenario of cardiac arrest due to ventricular fibrillation was used. Resuscitation teams consisted of three nurses, a resident and a staff physician. Using videotapes recorded during simulations, the activities of the teams were coded in 5-s intervals. Unnecessary interruptions were defined as any interruptions in cardiac massage of 10 s or more that were not caused by defibrillation or endotracheal intubation. Results: Twelve teams were studied. The total time of possible cardiac massage was 414 ± 125 s. In each team at least one unnecessary interruption occurred (range 1-5). Interruptions mounted up to 65 ± 40 s (range 20-155) or 16 ± 10% (range 5-41) of the total time of possible cardiac massage. Failure to swiftly resume cardiac massage after an unsuccessful defibrillation accounted for 14 of 39 episodes and for 44 ± 40% of the time of unnecessary interruptions. The debriefings revealed that participants had generally not noticed the unnecessary interruptions during the simulation. Conclusions: The present study identified a significant amount of unnecessary interruptions in cardiac massage. These interruptions were not noticed by the health-care workers involved.Keywords
This publication has 7 references indexed in Scilit:
- Interruption of cardiopulmonary resuscitation with the use of the automated external defibrillator in out-of-hospital cardiac arrestAnnals of Emergency Medicine, 2003
- Cardiopulmonary resuscitation of adults in the hospital: A report of 14 720 cardiac arrests from the National Registry of Cardiopulmonary ResuscitationResuscitation, 2003
- Adverse Outcomes of Interrupted Precordial Compression During Automated DefibrillationCirculation, 2002
- Importance of Continuous Chest Compressions During Cardiopulmonary ResuscitationCirculation, 2002
- Leadership of resuscitation teams: ‘Lighthouse Leadership’Resuscitation, 1999
- Adverse effects of interrupting precordial compression during cardiopulmonary resuscitationCritical Care Medicine, 1997
- Comparison of cardiopulmonary resuscitation techniques using video camera recordings.Emergency Medicine Journal, 1996