Automated carotid artery intima layer regional segmentation
Authors:
- Kristen M MeiburgerKristen M Meiburger
- Filippo MolinariFMFilippo Molinari
- U Rajendra AcharyaU Rajendra Acharya
- Luca SabaLSLuca Saba
- Paulo RodriguesPRPaulo Rodrigues
- William LiboniWLWilliam Liboni
- Andrew NicolaidesANAndrew Nicolaides
- Jasjit S SuriJSJasjit S Suri
- 21 June 2011
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (13) , 4073-4090
Abstract
Evaluation of the carotid artery wall is essential for the assessment of a patient's cardiovascular risk or for the diagnosis of cardiovascular pathologies. This paper presents a new, completely user-independent algorithm called carotid artery intima layer regional segmentation (CAILRS, a class of AtheroEdge™ systems), which automatically segments the intima layer of the far wall of the carotid ultrasound artery based on mean shift classification applied to the far wall. Further, the system extracts the lumen-intima and media-adventitia borders in the far wall of the carotid artery. Our new system is characterized and validated by comparing CAILRS borders with the manual tracings carried out by experts. The new technique is also benchmarked with a semi-automatic technique based on a first-order absolute moment edge operator (FOAM) and compared to our previous edge-based automated methods such as CALEX (Molinari et al 2010 J. Ultrasound Med. 29 399-418, 2010 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57 1112-24), CULEX (Delsanto et al 2007 IEEE Trans. Instrum. Meas. 56 1265-74, Molinari et al 2010 IEEE Trans. Ultrason. Ferroelectr. Freq. Control 57 1112-24), CALSFOAM (Molinari et al Int. Angiol. (at press)), and CAUDLES-EF (Molinari et al J. Digit. Imaging (at press)). Our multi-institutional database consisted of 300 longitudinal B-mode carotid images. In comparison to semi-automated FOAM, CAILRS showed the IMT bias of -0.035 ± 0.186 mm while FOAM showed -0.016 ± 0.258 mm. Our IMT was slightly underestimated with respect to the ground truth IMT, but showed uniform behavior over the entire database. CAILRS outperformed all the four previous automated methods. The system's figure of merit was 95.6%, which was lower than that of the semi-automated method (98%), but higher than that of the other automated techniques.Keywords
This publication has 19 references indexed in Scilit:
- An Integrated Approach to Computer-Based Automated Tracing and Its Validation for 200 Common Carotid Arterial Wall Ultrasound ImagesJournal of Ultrasound in Medicine, 2010
- Real-time Measurement System for Evaluation of the Carotid Intima-Media Thickness With a Robust Edge OperatorJournal of Ultrasound in Medicine, 2008
- Using the Hough Transform to Segment Ultrasound Images of Longitudinal and Transverse Sections of the Carotid ArteryUltrasound in Medicine & Biology, 2007
- Characterization of a Completely User-Independent Algorithm for Carotid Artery Segmentation in 2-D Ultrasound ImagesIEEE Transactions on Instrumentation and Measurement, 2007
- Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: correlation with quantitative coronary angiography and coronary intravascular ultrasound findingsEuropean Heart Journal, 2007
- Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filteringMedical & Biological Engineering & Computing, 2006
- Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid arteryIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2005
- Comments on: A methodology for evaluation of boundary detection algorithms on medical imagesIEEE Transactions on Medical Imaging, 2004
- Robust analysis of feature spaces: color image segmentation2002
- Mean shift, mode seeking, and clusteringIEEE Transactions on Pattern Analysis and Machine Intelligence, 1995