Heterogeneous model to evaluate CFD in intracranial bifurcation aneurysms treated with the WEB device to predict angiographic outcome
- 3 February 2023
- journal article
- research article
- Published by SAGE Publications in Interventional Neuroradiology
- Vol. 31 (3) , 315-323
Abstract
Introduction: The Woven EndoBridge device (WEB) was developed as an alternative to treat Wide-Necked bifurcation aneurysms. It has proven to be effective and safe, however, cases of recanalization have been reported. The purpose of this study was to evaluate and quantify hemodynamic parameters and indexes with CFD of the intracranial aneurysms before and after WEB simulation and to establish their relationship to complete occlusion. Materials and methods: Using the heterogeneous model based on the marching cubes algorithm, we created 3D representations of 27 bifurcated intracranial aneurysms treated with the single-layer WEB device to evaluate hemodynamics parameters with CFD, calculated with and without the WEB. Results: We observed a lower treatment entry concentration indices (ICI) (2.12 ± 1.31 versus 3.14 ± 0.93, p-value: 0.029) previous to placement of WEB and higher pre-treatment FN (7.56 ± 5.92 versus 3.35 ± 1.51, p-value: 0.018) and post-treatment FN (5.34 ± 5.89 versus 1.99 ± 0.83, p-value: 0.021) for cases with successful occlusions. Lower post-treatment SRa (197.81 ± 221.29 versus 80.02 ± 45.25, p-value: 0.044) and higher pre (0.11 ± 0.07 versus 0.25 ± 0.19, p-value: 0.011) and post-treatment MATT (0.69 ± 1.23 versus 1.02 ± 0.46, p-value: 0.006) were observed in non-occluded cases. Conclusions: In our CFD analysis of the hemodynamic parameters of IA, we found lower ICI before the placement of the WEB device and higher FN pre- and post-treatment for cases with successful occlusions. Non-occluded cases had lower post-treatment SRa and higher pre-treatment and post-treatment MATT.Keywords
This publication has 18 references indexed in Scilit:
- Safety and efficacy of aneurysm treatment with WEB: results of the WEBCAST studyJournal of Neurosurgery, 2016
- Computational fluid dynamics analysis of flow reduction induced by flow-diverting stents in intracranial aneurysms: a patient-unspecific hemodynamics change perspectiveJournal of NeuroInterventional Surgery, 2016
- WEB-DL Endovascular Treatment of Wide-Neck Bifurcation Aneurysms: Long-Term Results in a European SeriesAmerican Journal of Neuroradiology, 2015
- Single-Layer WEBs: Intrasaccular Flow Disrupters for Aneurysm Treatment—Feasibility Results from a European StudyAmerican Journal of Neuroradiology, 2015
- Estimation of Inlet Flow Rates for Image-Based Aneurysm CFD Models: Where and How to Begin?Annals of Biomedical Engineering, 2015
- TetGen, a Delaunay-Based Quality Tetrahedral Mesh GeneratorACM Transactions on Mathematical Software, 2015
- Association between hemodynamic conditions and occlusion times after flow diversion in cerebral aneurysmsJournal of NeuroInterventional Surgery, 2014
- Mind the Gap: Impact of Computational Fluid Dynamics Solution Strategy on Prediction of Intracranial Aneurysm Hemodynamics and Rupture Status IndicatorsAmerican Journal of Neuroradiology, 2013
- Characterization of volumetric flow rate waveforms at the carotid bifurcations of older adultsPhysiological Measurement, 2010
- Flow–area relationship in internal carotid and vertebral arteriesPhysiological Measurement, 2008