Abstract
In the last decade, the shear strength of concrete members with rectangular cross sections reinforced with fiber-reinforced polymers (FRPs) has received considerable attention. Yet no research seems to have investigated circular concrete members reinforced with FRP reinforcement under shear loads. This paper presents the results of an investigation of the shear strength and behavior of six circular concrete specimens reinforced with glass-FRP (GFRP) bars and spirals. The specimens, which measured 3,000 mm in length by 500 mm in diameter, were tested under four-point bending. The test parameters included the shear span-to-depth ratio (a/d) ranging from 1.5 to 3.0 and the GFRP spiral reinforcement ratio with different spiral spacings (100, 150, and 200 mm) and spiral diameters (13 and 15 mm). As designed, the specimens failed in shear due to GFRP spiral rupture or flexural-shear failure for the specimens with a/d>2.5 and strut crushing combined with spiral rupture for the specimens with a/d<2.5. The...

This publication has 15 references indexed in Scilit: